  • Title: Slit-lamp photography made easy by a spot metering system.
    Author: Khaw PT, Elkington AR.
    Journal: Br J Ophthalmol; 1988 Jun; 72(6):473-4. PubMed ID: 3390424.
    Abstract:
    The use of a standard 35 mm camera with a spot metering system to take slit-lamp photographs is described. This system is mounted on a standard Haag-Streit slit-lamp and can be used with good results even by inexperienced operators.