These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A selective ion monitoring assay for tributyltin and its degradation products.
    Author: Greaves J, Unger MA.
    Journal: Biomed Environ Mass Spectrom; 1988 May 15; 15(10):565-9. PubMed ID: 3408825.
    Abstract:
    Tributyltin (TBT) is a biocide which has been shown to enter the aquatic environment by release from antifouling paints. TBT is acutely toxic to some marine organisms at concentrations near 1 microgram l-1 and physiological changes may occur at low nanogram per liter concentrations. Gas chromatography/mass spectrometry (GC/MS) (methane chemical ionization) has been used for identification (full scanning) and quantification (selected ion monitoring) of TBT, dibutyltin (DBT) and monobutyltin (MBT). The butyltins were extracted from environmental water samples with hexane/0.2% tropolone and derivatized with hexyl magnesium bromide to form hexylbutyltins. Selected ion monitoring was at m/z 319 (TBT) and m/z 347 (DBT, MBT and tripentyltin, the internal standard). Calibration curves prepared in natural water were linear and detection limits were less than 2 ng l-1. GC/MS and GC with flame photometric detection were compared as quantification methods for environmental samples and were shown to give similar results at the low nanogram per liter levels.