These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Cobalt Levels and Pseudotumor Characteristics Vary due to Metal Ion Source: Modular Femoral Neck vs Metal-on-Metal Articulations.
    Author: McConnell ZA, Stambough JB, Barnes CL, Wilson BL, Mears SC.
    Journal: J Arthroplasty; 2021 Oct; 36(10):3490-3497. PubMed ID: 34172347.
    Abstract:
    BACKGROUND: This study examines cobalt levels and pseudotumor characteristics in a non-recalled modular femoral prosthesis. We sought to determine relationships between serum cobalt levels and pseudotumors following modular and metal-on-metal (MoM) total hip arthroplasty (THA), the location and size of pseudotumors, and changes to pseudotumor grade over time. METHODS: We retrospectively evaluated a cohort of 190 primary THAs implanted with a dual-modular femoral stem by one surgeon from 2005 to 2013. One hundred seventeen THAs used a cobalt-chromium modular neck (CoCrMN) component and non-MoM articulation, 63 THAs had a titanium neck component and MoM articulation, and 10 had a titanium neck component and polyethylene liner. Serum ion levels were recorded for all patients. Pseudotumor grade and location were measured by musculoskeletal-trained radiologists. RESULTS: Cobalt levels did not correlate to time after index arthroplasty. In the CoCrMN group, cobalt levels were elevated in 11 of 19 (57.9%) patients with pseudotumor compared to 14 of 19 (73.7%) in the MoM group. Pseudotumors were more often located lateral to the hip joint in the CoCrMN group compared to anteromedial following MoM arthroplasty. In CoCrMN THAs, pseudotumors were visualized in 12 of 51 (23.5%) initial MARS MRIs within 40 months compared to 5 of 66 (7.6%) performed later (P = .02). CONCLUSION: Pseudotumor characteristics differ between patients with CoCrMN designs vs those with an MoM articulation. Normal serum cobalt levels did not exclude the presence of a pseudotumor and routine MARS MRI should be included in follow-up of patients with this CoCrMN prostheses.
    [Abstract] [Full Text] [Related] [New Search]