These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: High voltage microsecond pulse generators with highly effective energy recuperation in cases of sharp changes in load impedance.
    Author: Korotkov SV, Aristov YV, Korotkov DA.
    Journal: Rev Sci Instrum; 2021 May 01; 92(5):054703. PubMed ID: 34243329.
    Abstract:
    An experimental generator of microsecond pulses with an output current amplitude of ∼1 kA and an output voltage amplitude of ∼1 kV was developed. The generator is able to operate on a load whose electrical resistance changes significantly during operation. Under these conditions, the generator ensures high stability of output pulse energy and effectively uses energy that is reflected from the load. Using this generator, a high voltage generator with an output voltage pulse amplitude of ∼30 kV was developed. The high voltage generator is designed to be used in electric discharge technologies. The results of the experiments are given in which the high voltage generator produced discharges in water at a repetition rate of 500 Hz. The amplitude of the discharge current pulse was ∼600 A, and the pulse rise time was ∼150 ns.
    [Abstract] [Full Text] [Related] [New Search]