These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Development & validation of LC-MS/MS assay for 5-amino-1-methyl quinolinium in rat plasma: Application to pharmacokinetic and oral bioavailability studies.
    Author: Awosemo O, Neelakantan H, Watowich S, Ma J, Wu L, Chow DS, Liang D.
    Journal: J Pharm Biomed Anal; 2021 Sep 10; 204():114255. PubMed ID: 34304009.
    Abstract:
    5-Amino-1-methyl quinolinium (5-AMQ) is a potent Nicotinamide N-methyl transferase (NNMT) inhibitor. NNMT is an enzyme that catalyzes the N-methylation of the endogenous substrate nicotinamide, as well as exogenous xenobiotics. NNMT is fundamental to cellular metabolism; NNMT is overexpressed in select tissues (e.g., adipose tissue, skeletal muscle, etc.) in pathophysiological conditions, making it a clinically relevant target for drug development in several chronic diseases including obesity and diabetes. The objective of this study was to develop and validate a simple, sensitive, and reproducible liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of 5-AMQ in rat plasma and urine samples. 5-AMQ was extracted from plasma and urine by protein precipitation. Chromatographic separation was achieved using an ACE® Excel™ C18 column (2 μm, 50 × 2.1 mm) with a binary gradient solvent system comprising of water (A) and acetonitrile (B) containing 0.1 % formic acid as the mobile phase. Analysis was performed using an API 4000 QTRAP hybrid triple quadruple mass spectrometer and multiple reaction monitoring (MRM) in positive mode at m/z transitions of 159.100 → 90.00 and 162.200 → 117.200 for 5-AMQ and the internal standard, respectively. The standard curves of 5-AMQ in rat urine and plasma samples were linear in the concentration range of 10-2500 ng/mL. The intra-day and inter-day precisions and accuracies for 5-AMQ at four concentration levels in rat plasma and urine samples were found to be within the 15 % FDA acceptance range. Similarly, the accuracy and precision of 5-AMQ quantification in samples diluted up to 20-fold using blank plasma were within the 15 % acceptable range. Furthermore, the extraction recoveries and matrix effects at three concentration levels of rat plasma samples ranged from 99.5 %-110.6 % and -6.1 %-14.1 %, respectively. 5-AMQ was stable in rat plasma samples subjected to standard storage, preparation, and handling conditions, with less than 15 % variation noted at two concentration levels. The validated, sensitive, and reproducible LC-MS/MS method for 5-AMQ in rat plasma and urine samples was effectively applied to a pharmacokinetic study in rats with IV and oral administration of 5-AMQ. 5-AMQ displayed substantial plasma exposures via IV and oral route, with a mean maximum plasma concentration of 2252 ng/mL after oral administration, mean area under the curve (AUC0-∞) of 3708 h.ng/mL and 14431 h.ng/mL for the IV and oral groups, respectively, mean terminal elimination half-life of 3.80 ± 1.10 h and 6.90 ± 1.20 h respectively after intravenous and oral dose, and a good oral bioavailability (F % = 38.4).
    [Abstract] [Full Text] [Related] [New Search]