These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Target coverage and cardiopulmonary sparing with the updated ESTRO-ACROP contouring guidelines for postmastectomy radiation therapy after breast reconstruction: a treatment planning study using VMAT and proton PBS techniques.
    Author: Milligan MG, Zieminski S, Johnson A, Depauw N, Rosado N, Specht MC, Liao EC, Jimenez RB.
    Journal: Acta Oncol; 2021 Nov; 60(11):1440-1451. PubMed ID: 34313520.
    Abstract:
    BACKGROUND: The European Society for Therapeutic Radiology and Oncology Advisory Committee in Radiation Oncology Practice (ESTRO-ACROP) recently released new contouring guidelines for postmastectomy radiation therapy (PMRT) after implant-based reconstruction (IBR). As compared to prior ESTRO guidelines, the new guidelines primarily redefined the chest wall (CW) target to exclude the breast prosthesis. In this study, we assessed the impact of these changes on treatment planning and dosimetric outcomes using volumetric-modulated arc therapy (VMAT) and proton pencil-beam scanning (PBS) therapy. METHODS: We performed a treatment planning study of 10 women with left-sided breast cancer who underwent PMRT after IBR. All target structures were delineated first using standard (ESTRO) breast contouring guidelines and then separately using the new (ESTRO-ACROP) guidelines. Standard organs-at-risk (OARs) and cardiac substructures were contoured. Four sets of plans were generated: (1) VMAT using standard ESTRO contours, (2) VMAT using new ESTRO-ACROP contours, (3) PBS using standard contours, and (4) PBS using new contours. RESULTS: VMAT plans using the new ESTRO-ACROP guidelines resulted in modest sparing of the left anterior descending coronary artery (LAD) (mean dose: 6.99 Gy standard ESTRO vs. 6.08 Gy new ESTRO-ACROP, p = 0.010) and ipsilateral lung (V20: 21.66% vs 19.45%, p = 0.017), but similar exposure to the heart (mean dose: 4.6 Gy vs. 4.3 Gy, p = 0.513), with a trend toward higher contralateral lung (V5: 31.0% vs 35.3%, p = 0.331) and CW doses (V5: 31.9% vs 35.4%, p = 0.599). PBS plans using the new guidelines resulted in further sparing of the heart (mean dose: 1.05 Gy(RBE) vs. 0.54 Gy(RBE), p < 0.001), nearly all cardiac substructures (LAD mean dose: 2.01 Gy(RBE) vs. 0.66 Gy(RBE), p < 0.001), and ipsilateral lung (V20: 16.22% vs 6.02%, p < 0.001). CONCLUSIONS: PMRT after IBR using the new ESTRO-ACROP contouring guidelines with both VMAT and PBS therapy is associated with significant changes in exposure to several cardiopulmonary structures.
    [Abstract] [Full Text] [Related] [New Search]