These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Does diaphragm ultrasound improve the rapid shallow breathing index accuracy for predicting the success of weaning from mechanical ventilation? Author: Fossat G, Daillet B, Desmalles E, Boulain T. Journal: Aust Crit Care; 2022 May; 35(3):233-240. PubMed ID: 34340902. Abstract: BACKGROUND: This prospective study investigated whether taking into account diaphragmatic excursion (DE) measured by ultrasonography would improve the performance of the rapid shallow breathing index (RSBI) to predict extubation success or failure. OBJECTIVES: The aim of the study was to compare the new composite index named the rapid shallow diaphragmatic index (RSDI), and the RSBI measured during a spontaneous breathing trial regarding their ability to predict the need for re-intubation at 72 h. METHODS: One hundred mechanically ventilated patients underwent daily 30-min spontaneous breathing trials (SBTs) under pressure support ventilation of 6 cm H2O and end-expiratory pressure of 0 cm H2O until the SBT was considered successful and followed by extubation. The performances of RSBI (respiratory rate/tidal volume) and of the ratio RSBI/DE measured at 5 and 25 min of the successful SBT were compared in terms of area under the receiver operating characteristics curve (AUC), for predicting extubation success at 72 h. As secondary analysis, extubation and weaning success at 7 d were also considered. As exploratory analyses, predictive indices incorporating both clinical characteristics, the DE, and ultrasound diaphragm thickening fraction (DTF) were investigated. RESULTS: RSBI and RSBI/DE showed AUCs with 95% confidence intervals consistently extending below 0.50, either at the 5th (0.55 [0.36-0.74] and 0.55 [0.34-0.75], respectively) or at the 25th minute of SBT (0.49 [0.27-0.71] and 0.50 [0.29-0.68], respectively) for predicting weaning success at 72 h or at 7 d (5th min: 0.53 [0.37-0.70] and 0.54 [0.37-0.70], respectively; 25th min: 0.54 [0.37-0.71] and 0.55 [0.39-0.71], respectively). An exploratory index incorporating the accessory respiratory muscle activity, DE, DTF, and respiratory rate at 5th min of SBT showed AUCs for predicting extubation success at 7 d in the 78 patients with DTF measurement (0.77 [0.64-0.90]) that were significantly higher than that of the RSBI (P = 0.017) and RSBI/DE (P < 0.001) in the same respective populations. CONCLUSIONS: The RSBI and the ratio RSBI/DE failed to predict weaning success when measured during an SBT performed under minimal pressure support. Predictive indices incorporating ultrasound DE and DTF may merit further investigation.[Abstract] [Full Text] [Related] [New Search]