These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality. Author: Blaise H, Remen T, Ambarki K, Weiland E, Kuehn B, Orry X, Laurent V. Journal: Eur J Radiol; 2021 Sep; 142():109873. PubMed ID: 34371309. Abstract: PURPOSE: To evaluate the image quality of an accelerated compressed-sensing single-breath-hold 3D magnetic resonance cholangiopancreatography (BH-CS-MRCP) prototype sequence compared to the standard 3D sequence with respiratory triggering (STD-MRCP) at 1.5 T and 3 T. To assess the individual factors that can affect image quality. METHOD: This is a retrospective analysis. Both sequences (BH-CS-MRCP and STD-MRCP) were performed in 200 patients at 1.5 T and 200 patients at 3 T. Overall image quality and the visualization of the bilio-pancreatic ducts were rated on a 5-point scale. Image sharpness and background suppression were rated on a 4-point scale. A double reading was performed in 50 patients to assess the inter-observer reproducibility. Individual characteristics studied were gender, age, BMI, ascites, abdominal surface and breath-hold quality. RESULTS: At 1.5 T, BH-CS-MRCP was inferior to STD-MRCP in terms of overall quality (p = 0.0046), background suppression (p < 0.0001), visualization of the cystic duct (p < 0.0001), the right bile duct (p = 0.0008), the left bile duct (p = 0.0152), and the main pancreatic duct (p < 0.0001). However, BH-CS-MRCP was sharper than STD-MRCP (p = 0.028). At 3 T, BH-CS-MRCP was superior to STD-MRCP for overall quality (p < 0.0001), sharpness (p < 0.0001), and visualization of the bilio-pancreatic ducts (p < 0.0001). Background signal was conversely better suppressed in STD-MRCP (p < 0.0001). At 1.5 T, the volume of ascites was inversely correlated with image quality for BH-CS-MRCP while BMI was inversely correlated with image quality for STD-MRCP. Breath-hold quality was correlated with image quality for BH-CS-MRCP at 1.5 T and 3 T. CONCLUSION: BH-CS-MRCP is feasible in clinical routine at 1.5 and 3 T, yielding significantly better perceived image quality at 3 T but not at 1.5 T. BH-CS-MRCP appears to be influenced by ascites whereas STD-MRCP is influenced by BMI at 1.5 T. This study was approved by the Ethics Review Board for Research in Medical Imaging (IRB: CRM-2003-065).[Abstract] [Full Text] [Related] [New Search]