These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Diagnostic possibility of the combination of exhaled nitric oxide and blood eosinophil count for eosinophilic asthma. Author: Li JH, Han R, Wang YB, Cheng M, Chen HY, Lei WH, Li L, Gao C, Zhao NN, Nie NF, Li ZY, Yin GQ, Huang S, He Y. Journal: BMC Pulm Med; 2021 Aug 09; 21(1):259. PubMed ID: 34372824. Abstract: BACKGROUND: Tests to identify reversible airflow limitation are important in asthma diagnosis, but they are time-consuming and it may be difficult for patients to cooperate. We aimed to evaluate whether the combination of fractional exhaled nitric oxide (FeNO) and blood eosinophil (B-Eos) can be used to distinguish some asthma patients who could avoid objective tests. METHODS: We conducted a retrospective cohort study on 7463 suspected asthma cases between January 2014 and December 2019 in Chongqing, China, and identified 2349 patients with complete FeNO, B-Eos count, and spirometry data. Asthma was diagnosed by clinicians by the criteria of recurrent respiratory symptoms and a positive bronchial-provocation or bronchodilation test (BPT, BPD). We evaluated the diagnostic accuracy of FeNO or B-Eos alone or both in combination for asthma using receiver operating characteristic (ROC) curve analysis. RESULTS: In this study, 824 patients were diagnosed with asthma. When FeNO and B-Eos counts were used in combination, the area under the ROC curve (AUC) for diagnosing asthma increased slightly (0.768 vs. 0.745 [FeNO] or 0.728 [B-Eos]; both P < 0.001). The odds ratio for having asthma increased progressively with a gradual increase in FeNO or B-Eos count (both P < 0.001; assessed using the Cochran-Armitage trend test). Further analysis of in-series combinations of different threshold values for these biomarkers indicated that moderately elevated biomarker levels (FeNO > 40 ppb and B-Eos > 300 cells/μl) support a diagnosis of asthma because diagnostic specificity was > 95% and the positive likelihood ratio (PLR) was > 10. This conclusion was verified when selecting the 2017-2019 data as the internal validation dataset. CONCLUSION: FeNO or B-Eos count alone is insufficient to accurately diagnose asthma. Patients with moderately elevated biomarkers (FeNO > 40 ppb and B-Eos > 300 cells/μl) could be diagnosed with asthma and avoid objective tests when such tests are not feasible.[Abstract] [Full Text] [Related] [New Search]