These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Subjective indoor air quality and thermal comfort among adults in relation to inspected and measured indoor environment factors in single-family houses in Sweden-the BETSI study. Author: Wang J, Norbäck D. Journal: Sci Total Environ; 2022 Jan 01; 802():149804. PubMed ID: 34455269. Abstract: Totally 1160 adults living in single-family houses in Sweden participated in a questionnaire survey on subjective indoor air quality (SIAQ). Inspectors investigated the dwellings and performed home measurements (mean indoor temperature 21.4 °C, mean indoor air humidity 34.2%, mean indoor air exchange rate 0.36 ac/h and mean moisture load indoor 1.7 g/m3). Totally 15.5% perceived draught, 28.0% perceived too high room temperature, 42.4% unstable room temperature, 36.8% too low room temperature, 19.6% stuffy air, 19.8% dry air and 29.9% dust or dirt. Measured room temperature was related to perception of room temperature. Higher relative air humidity was related to perceived unstable room temperature (OR = 1.70) and too low room temperature (OR = 1.96). Higher absolute air humidity was related to too high room temperature (OR = 1.21), unstable room temperature (OR = 1.34) and too low room temperature (OR = 1.35). Higher measured relative humidity, absolute air humidity and moisture load were all associated with stuffy air and unpleasant odor (OR = 1.45-1.97). Higher air exchange rate was related to less perceived unstable room temperature (OR = 0.93). Higher U value was related to draught (OR = 1.17), too low room temperature (OR = 1.09), unpleasant odor (OR = 1.12) and dust and dirt (OR = 1.07). New concrete slab foundation was related to less stuffy air (OR = 0.39) (vs. basement). Damp foundation was associated with more stuffy air (OR = 1.44) and unpleasant odor (OR = 1.61). Window pane condensation was related to stuffy air (OR = 1.88). Moldy odor reported by inspector was related to stuffy air (OR = 1.73). Observed mold in the attic was associated with more stuffy air and unpleasant odor. In conclusion, complaints of room temperature can indicate poor thermal environment. Higher air exchange rate can create a more stable thermal sensation. Excess indoor humidity, lower degree of thermal insulation, presence of window pane condensation and indoor dampness/mold can impair SIAQ. Higher ventilation and concrete slab foundation with underlying thermal insulation can improve SIAQ.[Abstract] [Full Text] [Related] [New Search]