These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Retro cervical tunneling to ensure correct placement for robotic-assisted transabdominal cerclage.
    Author: Suárez-Salvador E, Goya M, Acosta U, Vargas M, Bradbury M, Carreras E, Gil-Moreno A.
    Journal: Fertil Steril; 2021 Oct; 116(4):1195-1196. PubMed ID: 34579826.
    Abstract:
    OBJECTIVE: To demonstrate the step-by-step surgical technique of robotic-assisted transabdominal cerclage, highlighting a new posterior compartment approach. DESIGN: Stepwise explanation of a surgical technique using surgical video. SETTING: The procedure was performed at the Obstetrics and Gynecology Department, Hospital Vall d'Hebron in Barcelona, Spain, a tertiary medical center. The local institutional review board considers that case reports are exempt from research approval. PATIENT(S): A 26-year-old non-pregnant patient, with a history of cervical incompetence, three second-trimester losses, and vaginal cerclage failure during her previous pregnancy. INTERVENTION(S): Robotic-assisted transabdominal cerclage placement was performed. An 8-mm, 30° scope; monopolar scissors; and Maryland bipolar graspers were used. A uterine manipulator was used for better exposure. First, a bladder flap was created, and the uterine vessels were identified and skeletonized. Next, a window between the uterine vessels and the uterine cervix at the level of the cervical-isthmic junction was created bilaterally. At the posterior compartment, the dissection of the root of the uterosacral ligaments was carefully performed. A retrocervical pocket was created with monopolar scissors and sharp dissection. The procedure was finished with the Mersilene tape placement. First, the tape was passed through the window created in the right broad ligament, with a posterior-to-anterior direction, the retro cervical pocket, and finally through the left broad ligament. The knot was placed anteriorly and reperitonization was performed. In addition to this operation, robotic-assisted transabdominal cerclage was successfully performed in another six patients with good surgical and obstetrics outcomes. MAIN OUTCOME MEASURE(S): Intraoperative technique to ensure successful robot-assisted abdominal cerclage placement. RESULT(S): The patient became pregnant six months following the robotic-assisted transabdominal cerclage. Her pregnancy was closely followed up at the High-Risk Obstetric Unit, and she had no complications during pregnancy. An elective cesarean section was performed at 36 weeks with a healthy newborn baby that was discharged with the mother three days after delivery. CONCLUSION(S): The development of a retro cervical pocket during robotic-assisted transabdominal cerclage can be performed safely and effectively. It may help prevent displacement of the Mersilene tape during endoscopic knotting.
    [Abstract] [Full Text] [Related] [New Search]