These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Characterizing Particle Evacuation in the Setting of Positive-pressure Body Exhaust Suit Using a Novel Gloving Technique. Author: Sagers K, Shields JS, Pollock DC, Langfitt MK, Nishiyama SK. Journal: J Surg Orthop Adv; 2021; 30(3):166-169. PubMed ID: 34591006. Abstract: The sterility of the gown-glove interface during total joint arthroplasty is a key factor in preventing contamination of the surgical field. To compare the potential of gown-glove interface contamination with a novel gloving technique versus standard gloving technique. We performed a study quantifying potential gown-glove interface contamination using two different gloving techniques. A 5 μm fluorescent powder simulated potential bacterial contamination. Each group gowned and gloved each hand using a modified technique versus traditional technique. Ultraviolet light was used to measure contamination at the gown-glove interface after performing a simulated surgery. The modified gloving technique did not statistically reduce the contamination at the gown-glove interface compared to the traditional gloving technique (p = 0.27). Despite using a gloving technique recently described as decreasing contamination, we noted contamination at the interface after performing a simulated surgery with a positive pressure exhaust suit. Further study is needed. (Journal of Surgical Orthopaedic Advances 30(3):166-169, 2021).[Abstract] [Full Text] [Related] [New Search]