These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Blind color deconvolution, normalization, and classification of histological images using general super Gaussian priors and Bayesian inference.
    Author: Pérez-Bueno F, Vega M, Sales MA, Aneiros-Fernández J, Naranjo V, Molina R, Katsaggelos AK.
    Journal: Comput Methods Programs Biomed; 2021 Nov; 211():106453. PubMed ID: 34649072.
    Abstract:
    BACKGROUND AND OBJECTIVE: Color variations in digital histopathology severely impact the performance of computer-aided diagnosis systems. They are due to differences in the staining process and acquisition system, among other reasons. Blind color deconvolution techniques separate multi-stained images into single stained bands which, once normalized, can be used to eliminate these negative color variations and improve the performance of machine learning tasks. METHODS: In this work, we decompose the observed RGB image in its hematoxylin and eosin components. We apply Bayesian modeling and inference based on the use of Super Gaussian sparse priors for each stain together with prior closeness to a given reference color-vector matrix. The hematoxylin and eosin components are then used for image normalization and classification of histological images. The proposed framework is tested on stain separation, image normalization, and cancer classification problems. The results are measured using the peak signal to noise ratio, normalized median intensity and the area under ROC curve on five different databases. RESULTS: The obtained results show the superiority of our approach to current state-of-the-art blind color deconvolution techniques. In particular, the fidelity to the tissue improves 1,27 dB in mean PSNR. The normalized median intensity shows a good normalization quality of the proposed approach on the tested datasets. Finally, in cancer classification experiments the area under the ROC curve improves from 0.9491 to 0.9656 and from 0.9279 to 0.9541 on Camelyon-16 and Camelyon-17, respectively, when the original and processed images are used. Furthermore, these figures of merits are better than those obtained by the methods compared with. CONCLUSIONS: The proposed framework for blind color deconvolution, normalization and classification of images guarantees fidelity to the tissue structure and can be used both for normalization and classification. In addition, color deconvolution enables the use of the optical density space for classification, which improves the classification performance.
    [Abstract] [Full Text] [Related] [New Search]