These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Reliability of attachment level measurements using the cementoenamel junction and a plastic stent.
    Author: Clark DC, Chin Quee T, Bergeron MJ, Chan EC, Lautar-Lemay C, de Gruchy K.
    Journal: J Periodontol; 1987 Feb; 58(2):115-8. PubMed ID: 3469400.
    Abstract:
    Repeated measurements of attachment level appear to be important assessments in periodontal clinical trials, yet the lack of reliability for this assessment creates measurement error which in turn demands increased sample sizes or reduces the power of the test. A plastic occlusal stent has been developed as a fixed reference point to assess changes in probing depths over time and thus reflect differences in attachment levels. The advantages of this system over traditional methods have not been measured. The purpose of this study was to determine intra- and interexaminer reliability for probing depths from the stent and the CEJ. Paired measurements of attachment level using the stent produced correlation coefficients for inter- and intraexaminer readings of 0.84 and 0.76, respectively. For subgingival cementoenamel (CEJ) measurements, lower coefficients of 0.71 and 0.59 were found for inter- and intraexaminer paired readings, respectively. Thus, measurements using the stent appear to be more reliable than subgingival CEJ readings.
    [Abstract] [Full Text] [Related] [New Search]