These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Application of Compressed Sensing 3D MR cholangiopancreatography (CS-MRCP) with Contact-Free Physiological Monitoring (CFPM) for Pancreaticobiliary Disorders.
    Author: He M, Xu J, Wu Q, Wang X, Ren J, Wang X, Xue H, Jin Z.
    Journal: Acad Radiol; 2021 Nov; 28 Suppl 1():S148-S156. PubMed ID: 34756818.
    Abstract:
    RATIONAL AND OBJECTIVES: To prospectively evaluate the clinical feasibility of the magnetic resonance cholangiopancreatography (MRCP) protocol using both contact-free physiological monitoring (CFPM) and compressed sensing (CS) (CS-CFPM-MRCP) and to compare its performance with that of the standard navigator-triggered (NT) CS-NT-MRCP and NT-MRCP. MATERIALS AND METHODS: A total of 63 patients (36 males, 27 females, age range: 18-83 years, mean age: 52.30 ± 15.70 years) suspected with duct-related pathologies were prospectively enrolled and performed the three MRCP protocols randomly. The acquisition time was compared. The pancreaticobiliary system was divided into 12 segments and evaluated based on a five-point Likert scale and compared by the Friedman test with a post hoc test. The diagnostic performance of the 3 MRCP was evaluated by the AUC value and compared by Delong's test. The interobserver agreement was evaluated by Kendall's W test. RESULTS: Compared to NT-MRCP, the acquisition time of CS-NT-MRCP and CS-CFPM-MRCP was significantly decreased (both p < 0.001). There is no significant difference in the overall imaging quality (p > 0.05) between the NT-MRCP and CS-CFPM-MRCP protocols. CS-CFPM-MRCP depicted pancreatic duct and intrahepatic ducts better than CS-NT-MRCP (all p < 0.05) and was comparable with that of the NT-MRCP (all p > 0.05). For identification of abnormalities and diseases associated with MPD anatomy, the mean AUC value for NT-MRCP and CS-CFPM-MRCP were 0.896 (95%CI: 0.834, 0.958) and 0.905 (95%CI: 0.846, 0.964), which were significantly higher when compared to that for CS-NT-MRCP (0.713 [95%CI:0.622, 0.805]) (p = 0.001 and < 0.001). All evaluations showed good to excellent agreement (0.619-0.897). CONCLUSION: The combination of CS and CFPM is considered feasible for shortening the scan time of 3D free breath MRCP without impairing the imaging quality and CS-CFPM-MRCP is considered feasible for patients suspected with pancreaticobiliary diseases.
    [Abstract] [Full Text] [Related] [New Search]