These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Clinical outcomes in high-hypoglycaemia-risk patients with type 2 diabetes switching to insulin glargine 300 U/mL versus a first-generation basal insulin analogue in the United States : Results from the DELIVER High Risk real-world study. Author: Sullivan SD, Freemantle N, Gupta RA, Wu J, Nicholls CJ, Westerbacka J, Bailey TS. Journal: Endocrinol Diabetes Metab; 2022 Jan; 5(1):e00306. PubMed ID: 34807513. Abstract: AIMS: To compare 12-month clinical effectiveness of insulin glargine 300 units/mL (Gla-300) versus first-generation basal insulin analogues (BIAs) (insulin glargine 100 units/mL [Gla-100] or insulin detemir [IDet]) in patients with type 2 diabetes (T2D) who were at high risk of hypoglycaemia and switched from one BIA to a different one (Gla-300 or Gla-100/IDet) in a real-world setting. METHODS: DELIVER High Risk was a retrospective observational cohort study of 2550 patients with T2D who switched BIA to Gla-300 (Gla-300 switchers) and were propensity score-matched (1:1) to patients who switched to Gla-100 or IDet (Gla-100/IDet switchers). Outcomes were change in glycated haemoglobin A1c (HbA1c), attainment of HbA1c goals (<7% and <8%), and incidence and event rates of hypoglycaemia (all-hypoglycaemia and hypoglycaemia associated with an inpatient/emergency department [ED] contact). RESULTS: HbA1c reductions were similar following switching to Gla-300 or Gla-100/IDet (-0.51% vs. -0.53%; p = .67), and patients showed similar attainment of HbA1c goals. Patients in both cohorts had comparable all-hypoglycaemia incidence and event rates. However, the Gla-300 switcher cohort had a significantly lower risk of inpatient/ED-associated hypoglycaemia (adjusted odds ratio: 0.73, 95% confidence interval: 0.60-0.89; p = .002) and experienced significantly fewer inpatient/ED-associated hypoglycaemic events (0.21 vs. 0.33 events per patient per year; p < .001). CONCLUSION: In patients with T2D at high risk of hypoglycaemia, switching to Gla-300 or Gla-100/IDet achieved similar HbA1c reductions and glycaemic goal attainment, but Gla-300 switchers had a significantly lower risk of hypoglycaemia associated with an inpatient/ED contact during 12 months after switching.[Abstract] [Full Text] [Related] [New Search]