These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: An Evidence-Based Protocol for Manual Prone Positioning of Patients With ARDS.
    Author: Ryan P, Fine C, DeForge C.
    Journal: Crit Care Nurse; 2021 Dec 01; 41(6):55-60. PubMed ID: 34851387.
    Abstract:
    BACKGROUND: Manual prone positioning has been shown to reduce mortality among patients with moderate to severe acute respiratory distress syndrome, but it is associated with a high incidence of pressure injuries and unplanned extubations. This study investigated the feasibility of safely implementing a manual prone positioning protocol that uses a dedicated device. REVIEW OF EVIDENCE: A search of CINAHL and Medline identified multiple randomized controlled trials and meta-analyses that demonstrated both the reduction of mortality when prone positioning is used for more than 12 hours per day in patients with acute respiratory distress syndrome and the most common complications of this treatment. IMPLEMENTATION: An existing safe patient-handling device was modified to enable staff to safely perform manual prone positioning with few complications for patients receiving mechanical ventilation. All staff received training on the protocol and use of the device before implementation. EVALUATION: This study included 36 consecutive patients who were admitted to the medical intensive care unit at a large academic medical center because of hypoxemic respiratory failure/acute respiratory distress syndrome and received mechanical ventilation and prone positioning. Data were collected on clinical presentation, interventions, and complications. SUSTAINABILITY: Using the robust protocol and the low-cost device, staff can safely perform a low-volume, high-risk maneuver. This method provides cost savings compared with other prone positioning methods. CONCLUSIONS: Implementing a prone positioning protocol with a dedicated device is feasible, with fewer complications and lower costs than anticipated.
    [Abstract] [Full Text] [Related] [New Search]