These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: In Revision THA, Is the Re-revision Risk for Dislocation and Aseptic Causes Greater in Dual-mobility Constructs or Large Femoral Head Bearings? A Study from the Australian Orthopaedic Association National Joint Replacement Registry. Author: Hoskins W, Rainbird S, Dyer C, Graves SE, Bingham R. Journal: Clin Orthop Relat Res; 2022 Jun 01; 480(6):1091-1101. PubMed ID: 34978538. Abstract: BACKGROUND: Dislocation is one of the most common causes of a re-revision after a revision THA. Dual-mobility constructs and large femoral head bearings (≥ 36 mm) are known options for mitigating this risk. However, it is unknown which of these choices is better for reducing the risk of dislocation and all-cause re-revision surgery. It is also unknown whether there is a difference between dual-mobility constructs and large femoral head bearings according to the size of the acetabular component. QUESTIONS/PURPOSES: We used data from a large national registry to ask: In patients undergoing revision THA for aseptic causes after a primary THA performed for osteoarthritis, (1) Does the proportion of re-revision surgery for prosthesis dislocation differ between revision THAs performed with dual-mobility constructs and those performed with large femoral head bearings? (2) Does the proportion of re-revision surgery for all aseptic causes differ between revision THAs performed with dual-mobility constructs and those performed with large femoral head bearings? (3) Is there a difference when the results are stratified by acetabular component size? METHODS: Data from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) were analyzed for 1295 first-revision THAs for aseptic causes after a primary THA performed for osteoarthritis. The study period was from January 2008-when the first dual-mobility prosthesis was recorded-to December 2019. There were 502 dual-mobility constructs and 793 large femoral head bearings. There was a larger percentage of women in the dual-mobility construct group (67% [334 of 502]) compared with the large femoral head bearing group (51% [402 of 793]), but this was adjusted for in the statistical analysis. Patient ages were similar for the dual-mobility construct group (67 ± 11 years) and the large femoral head group (65 ± 12 years). American Society of Anesthesiologists (ASA) class and BMI distributions were similar. The mean follow-up was shorter for dual-mobility constructs at 2 ± 1.8 years compared with 4 ± 2.9 years for large femoral head bearings. The cumulative percent revision (CPR) was determined for a diagnosis of prosthesis dislocation as well as for all aseptic causes (excluding infection). Procedures using metal-on-metal bearings were excluded. The time to the re-revision was described using Kaplan-Meier estimates of survivorship, with right censoring for death or database closure at the time of analysis. The unadjusted CPR was estimated each year of the first 5 years for dual-mobility constructs and for each of the first 9 years for large femoral head bearings, with 95% confidence intervals using unadjusted pointwise Greenwood estimates. The apparent shorter follow-up of the dual-mobility construct group relates to the more recent increase in dual-mobility numbers recorded in the registry. The results were adjusted for age, gender, and femoral fixation. Results were subanalyzed for acetabular component sizes < 58 mm and ≥ 58 mm, set a priori on the basis of biomechanical and other registry data. RESULTS: There was no difference in the proportion of re-revision for prosthesis dislocation between dual-mobility constructs and large femoral head bearings (hazard ratio 1.22 [95% CI 0.70 to 2.12]; p = 0.49). At 5 years, the CPR of the re-revision for prosthesis dislocation was 4.0% for dual mobility constructs (95% CI 2.3% to 6.8%) and 4.1% for large femoral head bearings (95% CI 2.7% to 6.1%). There was no difference in the proportion of all aseptic-cause second revisions between dual-mobility constructs and large femoral head bearings (HR 1.02 [95% CI 0.76 to 1.37]; p = 0.89). At 5 years, the CPR of dual-mobility constructs was 17.6% for all aseptic-cause second revision (95% CI 12.6% to 24.3%) and 17.8% for large femoral head bearings (95% CI 14.9% to 21.2%). When stratified by acetabular component sizes less than 58 mm and at least 58 mm, there was no difference in the re-revision CPR for dislocation or for all aseptic causes between dual-mobility constructs and large femoral head bearings. CONCLUSION: Either dual-mobility constructs or large femoral head bearings can be used in revision THA, regardless of acetabular component size, as they did not differ in terms of re-revision rates for dislocation and all aseptic causes in this registry study. Longer term follow-up is required to assess whether complications develop with either implant or whether a difference in revision rates becomes apparent. Ongoing follow-up and comparison in a registry format would seem the best way to compare long-term complications and revision rates. Future studies should also compare surgeon factors and whether they influence decision-making between prosthesis options and second revision rates. Nested randomized controlled trials in national registries would seem a viable option for future research. LEVEL OF EVIDENCE: Level III, therapeutic study.[Abstract] [Full Text] [Related] [New Search]