These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Timely explantation of tobramycin-impregnated beads and bone cement to avoid haemodialysis in a patient with worsening renal failure.
    Author: Borick JJ, Balan S, Lichtenberger P, Bjork L.
    Journal: BMJ Case Rep; 2022 Feb 07; 15(2):. PubMed ID: 35131767.
    Abstract:
    A male patient with right total knee arthroplasty complicated by prosthetic joint infection on intravenous antimicrobials developed an acute kidney injury (AKI) with creatinine up to 7.3 mg/dL ('normal' range (0.5-1.2 mg/dL)) after hardware removal and tobramycin loaded polymethylmethacrylate beads and spacer placement. The AKI was initially attributed to intravenous vancomycin. Despite discontinuing vancomycin, the AKI worsened. A tobramycin level was collected and resulted at 5.5 µg/mL. Due to high suspicion for aminoglycoside-induced renal toxicity and to prevent haemodialysis, the antibiotic cement spacer with tobramycin-impregnated beads was removed. After the removal, tobramycin level rapidly decreased and renal functions improved. AKI is an increasingly recognised complication related to antibiotic-loaded bone cement (ALBC) due to the systemic absorption of antibiotics. With this case we highlight the early recognition of ALBC-induced renal toxicity necessitating explantation of ALBC and beads in order to prevent haemodialysis and emphasise monitoring aminoglycoside levels in the early postoperative period.
    [Abstract] [Full Text] [Related] [New Search]