These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Visualization of the distal tibial plafond articular surface using four established approaches and the efficacy of instrumented distraction: a cadaveric study.
    Author: Kleinertz H, Tessarzyk M, Schoof B, Nüchtern JV, Püschel K, Barg A, Frosch KH.
    Journal: Eur J Trauma Emerg Surg; 2022 Oct; 48(5):4031-4041. PubMed ID: 35296908.
    Abstract:
    PURPOSE: Direct visualization is a very effective method in accomplishing adequate articular surface reconstruction in fracture repair. This study investigates distal tibial plafond articular surface visibility using the anteromedial, anterolateral, posteromedial, and posterolateral approaches, the effect of instrumented distraction on visibility, and which zones of the articular surface are visible for each approach. METHODS: The anteromedial, anterolateral, posteromedial, and posterolateral approaches to the distal tibial plafond were performed on 16 cadaveric ankle specimens. The articular surface visualization for each approach was marked using an electrocautery device with manual and instrumented distraction. Articular surface visualization was photographically documented. Digital axial segmentation and quantitative analysis of the visualized distal tibial plafond articular surface were performed. RESULTS: With manual distraction, distal tibial plafond articular surface visualization, expressed in percent of overall articular surface, was limited to 9% (SD ± 9) for the anteromedial, 24% (SD ± 18) for the anterolateral, 26% (SD ± 10) for the posteromedial, and 30% (SD ± 18) for the posterolateral approaches. Using instrumented distraction significantly improved articular surface visualization in all instances (p < 0.001). The anteromedial approach visible articular surface increased to 63% (SD ± 13), the anterolateral to 72% (SD ± 22), the posteromedial to 62% (SD ± 11), and the posterolateral to 50% (± 17). CONCLUSION: This study demonstrates the efficacy of instrumented distraction when attempting surgical visualization of the distal tibial plafond articular surface. Knowledge of approach specific articular surface visibility may assist the surgeon in choosing the appropriate approach(es) based on case-specific distal tibial plafond fracture patterns. LEVEL OF EVIDENCE: IV, cadaver study.
    [Abstract] [Full Text] [Related] [New Search]