These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Bronchoscopic Lung Volume Reduction Coil Treatment for Severe Emphysema: A Systematic Review and Meta-Analysis of Individual Participant Data.
    Author: Roodenburg SA, Hartman JE, Deslée G, Herth FJF, Klooster K, Sciurba FC, Shah PL, Valipour A, Zoumot Z, Slebos DJ.
    Journal: Respiration; 2022; 101(7):697-705. PubMed ID: 35405678.
    Abstract:
    BACKGROUND: Lung volume reduction coil (LVR-coil) treatment provides a minimally invasive treatment option for severe emphysema patients which has been studied in multiple clinical trials. OBJECTIVES: The aim of the study was to assess the effect of LVR-coil treatment on pulmonary function, quality of life, and exercise capacity using individual participant data. METHOD: PubMed, Web of Science, and EMBASE were searched until May 17, 2021. Prospective single-arm and randomized controlled trials that evaluated the effect of LVR-coil treatment on forced expiratory volume in 1 s (FEV1), residual volume (RV), St. George Respiratory Questionnaire (SGRQ) total score, and/or 6-min walk distance (6MWD) and were registered in an official clinical trial database were eligible for inclusion. Individual patient data were requested, and a linear mixed effects model was used to calculate overall treatment effects. RESULTS: Eight trials were included in the final analysis, representing 680 individual patients. LVR-coil treatment resulted in a significant improvement in FEV1 at 3- (0.09 L [95% confidence interval (95% CI): 0.06-0.12]) and 6-month follow-up (0.07 L [95% CI: 0.03-0.10]), a significant reduction in RV at 3- (-0.45L [95% CI: -0.62 to -0.28]), 6- (-0.33L [95% CI: -0.52 to -0.14]), and 12-month follow-up (-0.36L [95% CI: -0.64 to -0.08]), a significant reduction in SGRQ total score at 3- (-12.3 points [95% CI: -15.8 to -8.8]), 6- (-10.1 points [95% CI: -12.8 to -7.3]), and 12-month follow-up (-9.8 points [95% CI: -15.0 to -4.7]) and a significant increase in 6MWD at 3-month follow-up (38 m [95% CI: 18-58]). CONCLUSIONS: LVR-coil treatment in emphysema patients results in sustained improvements in pulmonary function and quality of life and shorter lived improvements in exercise capacity. Since the owner of this LVR-coil has decided to stop the production and newer generations LVR-coils are currently being developed, these results can act as a reference for future studies and clinical guidance.
    [Abstract] [Full Text] [Related] [New Search]