These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Association of Phosphate-Containing versus Phosphate-Free Solutions on Ventilator Days in Patients Requiring Continuous Kidney Replacement Therapy. Author: Thompson Bastin ML, Stromberg AJ, Nerusu SN, Liu LJ, Mayer KP, Liu KD, Bagshaw SM, Wald R, Morris PE, Neyra JA. Journal: Clin J Am Soc Nephrol; 2022 May; 17(5):634-642. PubMed ID: 35477673. Abstract: BACKGROUND AND OBJECTIVES: Hypophosphatemia is commonly observed in patients receiving continuous KRT. Patients who develop hypophosphatemia may be at risk of respiratory and neuromuscular dysfunction and therefore subject to prolongation of ventilator support. We evaluated the association of phosphate-containing versus phosphate-free continuous KRT solutions with ventilator dependence in critically ill patients receiving continuous KRT. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: Our study was a single-center, retrospective, pre-post cohort study of adult patients receiving continuous KRT and mechanical ventilation during their intensive care unit stay. Zero-inflated negative binomial regression with and without propensity score matching was used to model our primary outcome: ventilator-free days at 28 days. Intensive care unit and hospital lengths of stay as well as hospital mortality were analyzed with a t test or a chi-squared test, as appropriate. RESULTS: We identified 992 eligible patients, of whom 649 (65%) received phosphate-containing solutions and 343 (35%) received phosphate-free solutions. In multivariable models, patients receiving phosphate-containing continuous KRT solutions had 12% (95% confidence interval, 0.17 to 0.47) more ventilator-free days at 28 days. Patients exposed to phosphate-containing versus phosphate-free solutions had 17% (95% confidence interval, -0.08 to -0.30) fewer days in the intensive care unit and 20% (95% confidence interval, - 0.12 to -0.32) fewer days in the hospital. Concordant results were observed for ventilator-free days at 28 days in the propensity score matched analysis. There was no difference in hospital mortality between the groups. CONCLUSIONS: The use of phosphate-containing versus phosphate-free continuous KRT solutions was independently associated with fewer ventilator days and shorter stay in the intensive care unit.[Abstract] [Full Text] [Related] [New Search]