These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Comparison of a newly developed high performance liquid chromatography method with diode array detection to a liquid chromatography tandem mass spectrometry method for the quantification of cabozantinib, dabrafenib, nilotinib and osimertinib in human serum - Application to therapeutic drug monitoring. Author: Aghai-Trommeschlaeger F, Zimmermann S, Gesierich A, Kalogirou C, Goebeler ME, Jung P, Pelzer T, Kurlbaum M, Klinker H, Isberner N, Scherf-Clavel O. Journal: Clin Biochem; 2022; 105-106():35-43. PubMed ID: 35483452. Abstract: OBJECTIVE: Liquid chromatography tandem mass spectrometry (LC-MS/MS) is a highly selective and sensitive method for the quantification of kinase inhibitors, yet not widely available in clinical routine for therapeutic drug monitoring (TDM). To provide a more accessible alternative, a high-performance liquid chromatography method with ultraviolet/diode array detection (HPLC-UV/DAD) to quantify cabozantinib, dabrafenib, nilotinib and osimertinib, was developed and validated. Results were compared to LC-MS/MS. METHOD: After liquid-liquid-extraction and reconstitution of the residue in 20 mM potassium dihydrogen phosphate (KH2PO4) (pH4.6), acetonitrile and methanol (50:25:25,v/v/v), chromatographic separation was achieved in 20.0 min using a Luna® C18(2)-HST column (100 × 2 mm, 2.5 μm), protected by a C18 guard column (4 × 2 mm) (column temperature: 30 °C, autosampler: 10 °C). Mobile phase A and B consisted of 20 mM KH2PO4 (pH4.9) and acetonitrile (9:1,v/v) and acetonitrile:20 mM KH2PO4 (pH4.9) (7:3,v/v), respectively. Gradient elution was performed at 200 µL/min. Analytes were quantified at 250, 280 and 330 nm, using sorafenib as internal standard. RESULTS: Calibration curves were linear (35-2,000 ng/mL). Method validation assays met requirements by U.S. Food and Drug Administration and European Medicines Agency. Compared to the more sensitive and specific LC-MS/MS, HPLC-UV/DAD showed a good correlation and a strong positive association (Kendall's tau 0.811¬-0.963, p < 0.05). Bland-Altman-plots revealed 100% (cabozantinib), 98.6% (dabrafenib), 98.6% (nilotinib) and 96.2% (osimertinib) of relative differences inside the limits of agreement. Regulatory agency criteria for sample reanalysis and cross validation were met (±20%-criterion:100% (cabozantinib), 94.3% (dabrafenib), 92% (nilotinib) and 84.6% (osimertinib). CONCLUSION: The developed HPLC-UV/DAD method is "fit-for-TDM" in clinical routine and serves as a genuine alternative to LC-MS/MS.[Abstract] [Full Text] [Related] [New Search]