These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: The calibration of rabbit tissue thromboplastins: experience of the Dutch Reference Laboratory for anticoagulant control.
    Author: van den Besselaar AM, Hermans J, van der Velde EA, Bussemaker-Verduyn den Boer E, van Halem-Visser LP, Jansen-Grüter R, Loeliger EA.
    Journal: J Biol Stand; 1986 Oct; 14(4):305-17. PubMed ID: 3558415.
    Abstract:
    A number of commercial rabbit tissue thromboplastins used in oral anticoagulant control have been calibrated against the first International Reference Preparation for thromboplastins. This was done in a three-stage procedure by one laboratory, each stage representing a different level of thromboplastin comparability. The calibration model recently recommended by ICTH and ICSH was tested. This model proved to be suitable, although a statistically significant aberration was observed for some of the thromboplastins. The bias introduced by using the model in these non-ideal cases was small compared to the overall variation of the International Normalized Ratio, being the universal scale for reporting the prothrombin time during oral anticoagulant control. Batch-to-batch calibration using lyophilized pooled plasmas could be reliably performed for several commercial thromboplastins.