These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Screen-printed graphite electrode modified with Co3O4nanoparticles and 2D graphitic carbon nitride as an effective electrochemical sensor for 4-aminophenol detection. Author: Jahani PM, Beitollahi H, Nejad FG, Dourandish Z, Di Bartolomeo A. Journal: Nanotechnology; 2022 Jul 04; 33(39):. PubMed ID: 35688102. Abstract: We fabricated a new electrochemical 4-aminophenol sensor based on a nanocomposite of Co3O4nanoparticles and graphite carbon nitride (Co3O4@g-C3N4), used for the modification of a screen-printed electrode (Co3O4@g-C3N4/SPE). The synthesized nanocomposite was characterized using field-emission scanning electron microscopy, energy-dispersive x-ray spectroscopy, x-ray diffraction and Fourier transform-infrared (FT-IR) techniques. The electro-oxidation of 4-aminophenol in phosphate buffer solution (pH = 7.0) was investigated via cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The peak current of oxidation in the optimized conditions had a linear relationship with various 4-aminophenol contents (0.05-780.0μM) with a correlation coefficient of 0.9996 and the limit of detection (S/N = 3) of 1.5 × 10-8M. The developed method was successful to determine 4-aminophenol in real specimens, with acceptable outcomes.[Abstract] [Full Text] [Related] [New Search]