  • Title: Neo-cusp Reconstruction Procedure for Aortic Regurgitation Induced by Transcatheter Occluder Device for Ventricular Septal Defect Closure.
    Author: Garekar S, Sheth R, Mali S, Dhake S, Mhatre A, Bind D, Kandavel D, Soni B, Malankar D.
    Journal: World J Pediatr Congenit Heart Surg; 2022 Jul; 13(4):495-498. PubMed ID: 35757954.
    Abstract:
    Aortic regurgitation after transcatheter device closure of a perimembranous ventricular septal defect is a known complication. We present the case of an 11-year-old boy with severe aortic valve regurgitation due to cusp perforation complicating previous device closure of a ventricular septal defect. The patient underwent successful aortic valve repair (neo-cusp reconstruction technique) by replacement of a cusp and shaving off of a rim of the device 5 years after device closure.