These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Thermoluminescence (TL), kinetic parameters and dosimetric features of Pakistani limestone. Author: Mahmood MM, Kakakhel MB, Wazir-Ud-Din M, Hayat S, Ahmad K, Ur-Rehman S, Siddique MT, Masood A, Ul-Haq A, Mirza SM. Journal: Appl Radiat Isot; 2022 Oct; 188():110357. PubMed ID: 35820299. Abstract: Thermoluminescence (TL), kinetic parameters and dosimetric features of Pakistani limestone (CaCO3) is reported in this study. Both compositional and structural analyses reveal that the material has a crystalline nature with rhombohedral structure and non-uniform crystallite size having major content of CaCO3. A powdered limestone sample of 30 mg is found to be the optimized weight for TL and other dosimetric studies. After irradiating the samples with a test dose of 100 Gy using a β source three composite glow peaks termed as P1, P2 and P3 are visible at 100, 230 and 330 °C respectively using a linear heating rate of 1 °C/s during the TL readout. The Coefficient of Variation (COV) is found to be about 4%. Kinetic parameters (i.e., frequency factor (f), activation energy (E), and the kinetic order (b)) are estimated using both first and second Order of kinetics using an in-house Computerized Glow Curve Deconvolution (GCD) software. The figure-of-merit (FOM) is found to be 2.12%. The distribution of continuum traps with activation energy in the range of 0.77-2.59 eV is observed in the kinetic parameter analysis of the glow peaks of the sample. The TL response in the dose range of 1-5 Gy (not reported previously) and linearity in the dose response in the dose range of 1-10 Gy is observed in samples of Pakistani limestone. The Minimum Detectable Dose (MDD) is 1.01 Gy clearly resembling the experimentally linear fitted results. After a fading study for a period of thirty days, only the first peak i.e., P1 majorly fades while no major change is observed in the amplitude of peaks P2 and P3. In addition, P1 is the main contributor fading by 92% within the first 24 h of irradiation while P2 fades by 30 %. However, P3 shows stability with a very minor fading of 0.05% within 24 h of irradiation. This study concludes that Pakistani limestone can be further assessed as a potential radiation dosimeter for various applications.[Abstract] [Full Text] [Related] [New Search]