These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Correlation of Apparent Diffusion Coefficient With Proliferation and Apoptotic Indexes in a Murine Model of Fibrosarcoma: Comparison of Four Methods for MRI Region of Interest Positioning.
    Author: Yang Y, Fang S, Tao J, Liu Y, Wang C, Yin Z, Chen B, Duan Z, Liu W, Wang S.
    Journal: J Magn Reson Imaging; 2023 May; 57(5):1406-1413. PubMed ID: 35864603.
    Abstract:
    BACKGROUND: Diffusion-weighted imaging (DWI) has demonstrated great potential in predicting the expression of tumor cell proliferation and apoptosis indexes. PURPOSE: To evaluate the impact of four region of interest (ROI) methods on interobserver variability and apparent diffusion coefficient (ADC) values and to examine the correlation of ADC values with Ki-67, Bcl-2, and P53 labeling indexes (LIs) in a murine model of fibrosarcoma. STUDY TYPE: Prospective, animal model. ANIMAL MODEL: A total of 22 female BALB/c mice bearing intramuscular fibrosarcoma xenografts. FIELD STRENGTH/SEQUENCE: A 3.0 T/T1-weighted fast spin-echo (FSE), T2-weighted fast relaxation fast spin-echo, and DWI PROPELLER FSE sequences. ASSESSMENT: Four radiologists measured ADC values using four ROI methods (oval, freehand, small-sample, and whole-volume). Immunohistochemical assessment of Ki-67, Bcl-2, and P53 LIs was performed. STATISTICAL TESTS: Interclass correlation coefficient (ICC), one-way analysis of variance followed by LSD-t post hoc analysis, and Pearson correlation test were performed. The statistical threshold was defined as a P-value of <0.05. RESULTS: All ROI methods for ADC measurements showed excellent interobserver agreement (ICC range, 0.832-0.986). The ADC values demonstrated significant differences among the four ROI methods. The ADC values for oval, freehand, small-sample, and whole-volume ROI methods showed a moderately negative correlation with Ki-67 (r = -0.623; r = -0.629; r = -0.642, and r = -0.431) and Bcl-2 (r = -0.590; r = -0.597; r = -0.659, and r = -0.425) LIs, but no correlation with P53 LI (r = 0.364, P = 0.104; r = 0.350, P = 0.120; r = 0.379, P = 0.091; r = 0.390, P = 0.080). DATA CONCLUSION: The ADC value can be used to evaluate cell proliferation and apoptosis indexes in a murine model of fibrosarcoma, employing the small-sample ROI as a reliable method. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 3.
    [Abstract] [Full Text] [Related] [New Search]