These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Diagnostic accuracy of transient elastography in diagnosing clinically significant portal hypertension in patients with chronic liver disease: a systematic review and meta-analysis. Author: Kumar A, Maruyama H, Arora A, Sharma P, Anikhindi SA, Bansal N, Kumar M, Ranjan P, Sachdeva M, Khare S. Journal: J Med Ultrason (2001); 2022 Jul; 49(3):333-346. PubMed ID: 35876975. Abstract: PURPOSE: Liver stiffness measurement using transient elastography (TE-LSM) is a promising noninvasive alternative to hepatic venous pressure gradient (HVPG) for diagnosing clinically significant portal hypertension (CSPH). However, previous studies have yielded conflicting results. We evaluated the correlation between TE-LSM and HVPG and the performance of TE-LSM in diagnosing CSPH (HVPG ≥ 10 mmHg). METHODS: We conducted a systematic review and meta-analysis by searching PubMed and Scopus databases for relevant literature evaluating the clinical usefulness of TE for diagnosing CSPH in patients with chronic liver disease. RESULTS: Twenty-six studies (4337 patients with valid TE and HVPG) met our inclusion criteria. The median correlation coefficient of TE with HVPG was 0.70 (range 0.36-0.86). The weighted mean of optimal cut-off of liver stiffness value for diagnosing CSPH was 22.8 kPa (95% CI 22.7-23.0 kPa). The summary sensitivity and specificity were 79% (95% CI 74-84%) and 88% (95% CI 84-91%), respectively. The area under the hierarchical summary receiver operating characteristic (HSROC) curve was 0.91 (95% CI 0.88-0.93) according to the bivariate model. One limitation of the study was significant heterogeneity in the results of summary sensitivity and specificity (I2 83 and 74%, respectively). The heterogeneity could be explained by the variable liver stiffness cut-offs used in studies. The meta-regression plot revealed that as the optimal cut-off increased, the sensitivity decreased, the specificity increased, and vice versa. CONCLUSIONS: Liver stiffness measurement using TE correlates well with HVPG, and a liver stiffness cut-off value of 22.8 kPa shows a high accuracy for diagnosing CSPH. Thus, use of TE should be integrated into clinical practice for noninvasive diagnosis of CSPH.[Abstract] [Full Text] [Related] [New Search]