These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Ultra-High-Field 7 T Magnetic Resonance Imaging Including Dynamic and Static Contrast-Enhanced T1-Weighted Imaging Improves Detection of Secreting Pituitary Microadenomas. Author: Eisenhut F, Schlaffer SM, Hock S, Heynold E, Kremenevski N, Bluemcke I, Buchfelder M, Doerfler A, Schmidt MA. Journal: Invest Radiol; 2022 Sep 01; 57(9):567-574. PubMed ID: 35925660. Abstract: OBJECTIVE: A prospective preoperative evaluation of 7 T ultra-high-field magnetic resonance imaging (MRI) in patients with suspected pituitary microadenomas for both adenoma detection and intrasellar localization compared with 3 T MRI was carried out. MATERIALS AND METHODS: Patients underwent prospective preoperative standardized 3 and 7 T MRI. A distinct qualitative (lesion detection, intrasellar lesion location) and quantitative (lesion diameters, T1/T2 signal intensity ratio of the lesion to normal pituitary gland tissue) analysis was performed, along with an evaluation of image quality (IQ) regarding overall IQ, anatomical parameters, and artifacts; the findings of the qualitative analysis were compared with intraoperative findings and endocrinological outcomes. RESULTS: Sixteen patients (mean age, 43 ± 16 years; 13 women) with pituitary microadenomas were included. Using 7 T MRI allowed the detection of 15 microadenomas-3 more than 3 T MRI. In addition, 7 T MRI allowed more precise lesion localization with 93.75% (15/16) agreement with intraoperative findings, compared with 75% (12/16) agreement using 3 T MRI. Lesion diameters showed no significant difference between 3 and 7 T MRI. T1 and T2 signal intensity ratio between microadenomas and normal pituitary gland tissue were higher in 7 T MRI than in 3 T MRI. The overall IQ and the IQ of each anatomical parameter of 7 T MRI were rated higher than those of 3 T MRI. No significant differences in susceptibility or head motion artifacts were observed between 3 and 7 T MRI; however, 7 T MRI was more susceptible to pulsation artifacts. CONCLUSION: Ultra-high-field MRI surpasses 3 T MRI in pituitary microadenoma detection and enables more precise delineation with higher correlation with intraoperative findings. Thus, 7 T sellar imaging is a promising option-especially in previously magnetic resonance-negative patients with endocrinologically confirmed hormone oversecretion-and helps reduce the need for invasive diagnostics.[Abstract] [Full Text] [Related] [New Search]