These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Assessing the accuracy of [18F]PSMA-1007 PET/CT for primary staging of lymph node metastases in intermediate- and high-risk prostate cancer patients.
    Author: Ingvar J, Hvittfeldt E, Trägårdh E, Simoulis A, Bjartell A.
    Journal: EJNMMI Res; 2022 Aug 09; 12(1):48. PubMed ID: 35943665.
    Abstract:
    BACKGROUND: [18F]PSMA-1007 is a promising tracer for integrated positron emission tomography and computed tomography (PET/CT). OBJECTIVE: Our aim was to assess the diagnostic accuracy of [18F]PSMA-1007 PET/CT for primary staging of lymph node metastasis before robotic-assisted laparoscopy (RALP) with extended lymph node dissection (ePLND). DESIGN, SETTING AND PARTICIPANTS: The study was a retrospective cohort in a tertiary referral center. Men with prostate cancer that underwent surgical treatment for intermediate- or high-risk prostate cancer between May 2019 and August 2021 were included. INTERVENTIONS: [18F]PSMA-1007 PET/CT for initial staging followed by RALP and ePLND. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSES: Sensitivity and specificity were calculated both for the entire cohort and for patients with lymph node metastasis ≥ 3 mm. Positive (PPV) and negative (NPV) predictive values were calculated. RESULTS AND LIMITATIONS: Among 104 patients included in the analyses, 26 patients had lymph node metastasis based on pathology reporting and metastases were ≥ 3 mm in size in 13 of the cases (50%). In the entire cohort, the sensitivity and specificity of [18F]PSMA-1007 were 26.9% (95% confidence interval (CI); 11.6-47.8) and 96.2% (95% CI; 89.2-99.2), respectively. The sensitivity and specificity of [18F]PSMA-1007 to detect a lymph node metastasis ≥ 3 mm on PET/CT were 53.8% (95% CI; 25.1-80.8) and 96.7% (95% CI; 90.7-99.3), respectively. PPV was 70% and NPV 93.6%. CONCLUSIONS: In primary staging of intermediate- and high-risk prostate cancer, [18F]PSMA-1007 PET/CT is highly specific for prediction of lymph node metastases, but the sensitivity for detection of metastases smaller than 3 mm is limited. Based on our results, [18F]PSMA-1007 PET/CT cannot completely replace ePLND. This study investigated the use of an imaging method based on a prostate antigen-specific radiopharmaceutical tracer to detect lymph node prostate cancer metastasis. We found that it is unreliable to discover small metastasis.
    [Abstract] [Full Text] [Related] [New Search]