These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Dosimetric analysis of MR-LINAC treatment plans for salvage spine SBRT re-irradiation.
    Author: Han EY, Yeboa DN, Briere TM, Yang J, Wang H.
    Journal: J Appl Clin Med Phys; 2022 Oct; 23(10):e13752. PubMed ID: 36004700.
    Abstract:
    PURPOSE: We investigated the feasibility of thoracic spine stereotactic body radiotherapy (SBRT) using the Elekta Unity magnetic resonance-guided linear accelerator (MRL) in patients who received prior radiotherapy. We hypothesized that Monaco treatment plans can improve the gross tumor volume minimum dose (GTVmin) with spinal cord preservation and maintain consistent plan quality during daily adaptation. METHODS: Pinnacle clinical plans for 10 patients who underwent thoracic spine SBRT (after prior radiotherapy) were regenerated in the Monaco treatment planning system for the Elekta Unity MRL using 9 and 13 intensity-modulated radiotherapy (IMRT) beams. Monaco adapt-to-position (ATP) and adapt-to-shape (ATS) workflow plans were generated using magnetic resonance imaging with a simulated daily positional setup deviation, and these adaptive plans were compared with Monaco reference plans. Plan quality measures included target coverage, Paddick conformity index, gradient index, homogeneity index, spinal cord D0.01cc , esophagus D0.01cc , lung V10, and skin D0.01cc . RESULTS: GTVmin values from the Monaco 9-beam and 13-beam plans were significantly higher than those from Pinnacle plans (p < 0.01) with similar spinal cord dose. Spinal cord D0.01cc , esophagus D0.01cc , and lung V10 did not statistically differ among the three plans. The electron-return effect did not induce remarkable dose effects around the lungs or skin. While in the ATP workflow, a large increase in GTVmin was observed at the cost of a 10%-50% increase in spinal cord D0.01cc , in the ATS workflow, the spinal cord dose increase was maintained within 3% of the reference plan. CONCLUSION: These findings show that MRL plans for thoracic spine SBRT are safe and feasible, allowing tumor dose escalation with spinal cord preservation and consistent daily plan adaptation using the ATS workflow. Careful plan review of hot spots and lung dose is necessary for safe MRL-based treatment.
    [Abstract] [Full Text] [Related] [New Search]