These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: [Transcutaneous and intracutaneous pO2 measurements in the assessment of peripheral arterial occlusive diseases]. Author: Reuter U, Setlak P, Petrow C, Altmann E, Sinz V. Journal: Z Gesamte Inn Med; 1987 Apr 01; 42(7):178-82. PubMed ID: 3604349. Abstract: The purpose of the study was to compare the results of intra- and transcutaneous pO2-measurements of patients suffering from an arterial occlusive disease of the lower extremities (Fontaine I-IV) with that of 20 healthy volunteers. The measurements were performed by one transcutaneous and two intracutaneous pO2-electrodes on the dorsum of the foot. As reference we used the ratio pf/pft of the venous occlusion plethysmography of the calf. Already at rest the transcutaneous pO2 allows a significant separation of healthy persons and patients of Fontaine II. After a 3-minute ischemic period the greatly changed time parameters 'delay-time', 'half-time of the pO2 increase' as well as the 'pO2 recovery time' permit a significant separation of Fontaine III from healthy persons and Fontaine II. The findings show that both methods complete one another. The value of a local pO2 measurement for an individual therapy control is emphasized.[Abstract] [Full Text] [Related] [New Search]