These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: High-fidelity, high-spatial-resolution diffusion magnetic resonance imaging of ex vivo whole human brain at ultra-high gradient strength with structured low-rank echo-planar imaging ghost correction.
    Author: Ramos-Llordén G, Lobos RA, Kim TH, Tian Q, Witzel T, Lee HH, Scholz A, Keil B, Yendiki A, Bilgiç B, Haldar JP, Huang SY.
    Journal: NMR Biomed; 2023 Feb; 36(2):e4831. PubMed ID: 36106429.
    Abstract:
    Diffusion magnetic resonance imaging (dMRI) of whole ex vivo human brain specimens enables three-dimensional (3D) mapping of structural connectivity at the mesoscopic scale, providing detailed evaluation of fiber architecture and tissue microstructure at a spatial resolution that is difficult to access in vivo. To account for the short T2 and low diffusivity of fixed tissue, ex vivo dMRI is often acquired using strong diffusion-sensitizing gradients and multishot/segmented 3D echo-planar imaging (EPI) sequences to achieve high spatial resolution. However, the combination of strong diffusion-sensitizing gradients and multishot/segmented EPI readout can result in pronounced ghosting artifacts incurred by nonlinear spatiotemporal variations in the magnetic field produced by eddy currents. Such ghosting artifacts cannot be corrected with conventional correction solutions and pose a significant roadblock to leveraging human MRI scanners with ultrahigh gradients for ex vivo whole-brain dMRI. Here, we show that ghosting-correction approaches that correct for either polarity-related ghosting or shot-to-shot variations in a separate manner are suboptimal for 3D multishot diffusion-weighted EPI experiments in fixed human brain specimens using strong diffusion-sensitizing gradients on the 3-T Connectom MRI scanner, resulting in orientationally biased dMRI estimates. We apply a recently developed advanced k-space reconstruction method based on structured low-rank matrix (SLM) modeling that handles both polarity-related ghosting and shot-to-shot variation simultaneously, to mitigate artifacts in high-angular resolution multishot dMRI data acquired in several fixed human brain specimens at 0.7-0.8-mm isotropic spatial resolution using b-values up to 10,000 s/mm2 and gradient strengths up to 280 mT/m. We demonstrate the improved mapping of diffusion tensor imaging and fiber orientation distribution functions in key neuroanatomical areas distributed across the whole brain using SLM-based EPI ghost correction compared with alternative techniques.
    [Abstract] [Full Text] [Related] [New Search]