These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Pediatric reference interval verification for 17 specialized immunoassays and cancer markers on the Abbott Alinity i system in the CALIPER cohort of healthy children and adolescents. Author: Bohn MK, Wilson S, Schneider R, Massamiri Y, Randell EW, Adeli K. Journal: Clin Chem Lab Med; 2023 Jan 27; 61(1):123-132. PubMed ID: 36117243. Abstract: OBJECTIVES: Clinical laboratory investigation of autoimmune, metabolic, and oncologic disorders in children and adolescents relies on appropriateness of reference intervals (RIs). The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) previously established comprehensive pediatric RIs for specialized immunoassays on the Abbott ARCHITECT system. Herein, we aim to verify performance on new Alinity i assays by evaluating sera collected from healthy children as per Clinical and Laboratory Standards Institute (CLSI) EP-28A3C guidelines. METHODS: Precision, linearity, and method comparison experiments were completed for 17 specialized Alinity immunoassays, including cancer antigens, autoimmune peptides, and hormones. Sera collected from healthy children and adolescents (birth-18 years, n=100) were evaluated. CLSI-based verification was completed using previously established CALIPER RIs for ARCHITECT assays as the reference. RESULTS: Of 17 specialized immunoassays assays, only anti-cyclic citrullinated peptides (anti-CCP) did not meet acceptable verification criterion (i.e., ≥90% of results within ARCHITECT reference CI). Anti-thyroglobulin, anti-thyroid peroxidase, and carcinoembryonic antigen did not require age-specific consideration beyond one year of age, with 63, 91, and 80% of samples equalling the limit of detection, respectively. Estimates were separated by sex for relevant assays (e.g., sex hormone binding globulin, total and free prostate specific antigen). CONCLUSIONS: Findings support transferability of pediatric RIs on ARCHITECT system to the Alinity system for 16 specialized immunoassays in the CALIPER cohort and will be a useful resource for pediatric clinical laboratories using Alinity assays. Further work is needed to establish evidence-based interpretative recommendations for anti-CCP and continue to evaluate pediatric RI acceptability for newly available assay technologies.[Abstract] [Full Text] [Related] [New Search]