These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Robotic guidance for percutaneous placement of triangular osteosynthesis in vertically unstable sacrum fractures: a single-center retrospective study. Author: Liu ZJ, Gu Y, Jia J. Journal: J Orthop Surg Res; 2023 Jan 04; 18(1):8. PubMed ID: 36597117. Abstract: BACKGROUND: To evaluate the effectiveness and safety of robot-aided percutaneous triangular osteosynthesis combined with close reduction for vertically unstable sacrum fractures (VUSFs). METHODS: The data on 21 patients of the VUSF were retrospectively analyzed from November 2016 to January 2021. According to Denis classification, there were 3 cases in zone I, 11 cases in zone II, and 7 case in zone III. The main perioperative indicators were recorded. The maximal angulation and displacement deviations of the screws were analyzed by comparing the planned trajectory with the actual position. Postoperative X-ray radiographs and CT scans were obtained for evaluating the reduction quality. Functional outcome was scored with Majeed criterion. RESULTS: Fourteen patients of the unilateral VUSF and 7 patients of the bilateral VUSF underwent unilateral and bilateral triangular osteosynthesis with robotic assistance, respectively. No intraoperative neurovascular injuries and postoperative infection occurred. All patients were followed up for at least 12 months. The average operation time of posterior pelvic ring was 111.4 min, with the mean intraoperative bleeding of 110.5 ml. A total of 58 pedicle and iliosacral screws were implanted with robotic assistance. Of those, 52 screws were in the cancellous bone except 4 pedicle and 2 iliosacral screws cutting the cortical bone. The angulation and displacement deviations of the screws were 4.2° ± 2.5° and 1.7 ± 0.9 mm, respectively. The average displacement of the sacral fracture was reduced from 19.7 mm preoperatively to 3.1 mm postoperatively. According to Matta's criterion, the reduction quality was graded as "excellent" in 13 patients and "good" in 8. All sacral fractures healed within 6 months except one fracture with nonunion. The mean Majeed score at the last follow-up was 89.6. CONCLUSIONS: Robot-aided triangular osteosynthesis combined with close reduction provide a safe and reliable option for percutaneous treatment of the fresh VUSF, with a high accuracy of iliosacral and pedicle screw implantation except insertion of iliac screws. Meanwhile, the technique may help to reduce incision-related complications.[Abstract] [Full Text] [Related] [New Search]