These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS)-based candidate reference measurement procedure (RMP) for the quantification of gabapentin in human serum and plasma. Author: Salzmann L, Wild J, Singh N, Schierscher T, Liesch F, Bauland F, Geistanger A, Risch L, Geletneky C, Seger C, Taibon J. Journal: Clin Chem Lab Med; 2023 Oct 26; 61(11):1955-1966. PubMed ID: 36689915. Abstract: OBJECTIVES: To describe and validate a reference measurement procedure (RMP) for gabapentin, employing quantitative nuclear magnetic resonance (qNMR) spectroscopy to determine the absolute content of the standard materials in combination with isotope dilution-liquid chromatograph-tandem mass spectrometry (ID-LC-MS/MS) to accurately measure serum and plasma concentrations. METHODS: A sample preparation protocol based on protein precipitation in combination with LC-MS/MS analysis using a C8 column for chromatographic separation was established for the quantification of gabapentin. Assay validation and determination of measurement uncertainty were performed according to guidance from the Clinical and Laboratory Standards Institute, the International Conference on Harmonization, and the Guide to the expression of uncertainty in measurement. ID-LC-MS/MS parameters evaluated included selectivity, specificity, matrix effects, precision and accuracy, inter-laboratory equivalence, and uncertainty of measurement. RESULTS: The use of qNMR provided traceability to International System (SI) units. The chromatographic assay was highly selective, allowing baseline separation of gabapentin and the gabapentin-lactam impurity, without observable matrix effects. Variability between injections, preparations, calibrations, and days (intermediate precision) was <2.3%, independent of the matrix, while the coefficient of variation for repeatability was 0.9-2.0% across all concentration levels. The relative mean bias ranged from -0.8-1.0% for serum and plasma samples. Passing-Bablok regression analysis indicated very good inter-laboratory agreement; the slope was 1.00 (95% confidence interval [CI] 0.98 to 1.03) and the intercept was -0.05 (95% CI -0.14 to 0.03). Pearson's correlation coefficient was ≥0.996. Expanded measurement uncertainties for single measurements were found to be ≤5.0% (k=2). CONCLUSIONS: This analytical protocol for gabapentin, utilizing traceable and selective qNMR and ID-LC-MS/MS techniques, allows for the standardization of routine tests and the reliable evaluation of clinical samples.[Abstract] [Full Text] [Related] [New Search]