These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial.
    Author: Tan HS, Nagarajan S, Chan JJI, Tan CW, Sultana R, Sia ATH, Sng BL.
    Journal: BMC Anesthesiol; 2023 Jan 26; 23(1):33. PubMed ID: 36703120.
    Abstract:
    BACKGROUND: The optimal treatment of hypotension during spinal anaesthesia is uncertain. A novel double intravenous vasopressor automated (DIVA) system reduces hypotension compared to standard care, and was subsequently modified to an advanced-DIVA (ADIVA) system. The primary objective was to compare ADIVA versus DIVA on incidence of hypotension (systolic BP (SBP) < 80% baseline). METHODS: We conducted a randomized-controlled trial in women undergoing elective cesarean delivery under spinal anesthesia. SBP and heart rate were measured continuously using a Nexfin monitor. ADIVA delivered 25 μg phenylephrine (heart rate > 60 beats.min-1) or 2 mg ephedrine (heart rate < 60 beats.min-1) at SBP 90 to 110% of baseline, 50 μg phenylephrine or 4 mg ephedrine at SBP 80 to 90%, and 75 μg phenylephrine or 6 mg ephedrine at SBP < 80%. ADIVA calculated the trend of SBP; vasopressors were administered rapidly if SBP trended downward, or 30 s if SBP trended upward. In contrast, DIVA delivered 25 μg phenylephrine or 2 mg ephedrine at SBP 90 to 100% of baseline, and 50 μg phenylephrine or 4 mg ephedrine at SBP < 90%. Boluses were followed by a 10-s lockout. Other outcomes included hypertension (SBP > 120% baseline), vasopressor consumption, clinical outcomes, and performance measures from spinal anesthesia to fetal delivery. RESULTS: We analyzed 94 parturients (ADIVA: n = 46, DIVA: n = 48), with no difference in the incidence of hypotension between ADIVA (78.3%) and DIVA (83.3%, p = 0.677). ADIVA had significantly higher proportion of hypotensive SBP readings, lower phenylephrine consumption and higher umbilical arterial pH. There was no difference in hypertension, bradycardia, ephedrine consumption, intravenous fluid volume, nausea/vomiting, Apgar scores, and umbilical venous pH or lactate. ADIVA maintained SBP higher above baseline with greater fluctuation than DIVA. CONCLUSION: ADIVA was associated with a greater proportion of hypotensive SBP readings, reduced phenylephrine consumption, and increased umbilical arterial pH than DIVA. Further research is needed to determine the optimal method of vasopressor delivery in parturients undergoing cesarean delivery. TRIAL REGISTRATION: This study was registered on Clinicaltrials.gov registry (NCT03620942) on 08/08/2018.
    [Abstract] [Full Text] [Related] [New Search]