These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Accuracy and processing time of kidney volume measurement methods in rodents polycystic kidney disease models: superiority of semiautomated kidney segmentation. Author: Doss MC, Mullen S, Roye R, Zhou J, Chumley P, Mrug E, Wallace DP, Qian F, Harris PC, Yoder BK, Kim H, Mrug M. Journal: Am J Physiol Renal Physiol; 2023 Apr 01; 324(4):F423-F430. PubMed ID: 36794756. Abstract: Measurement of total kidney volume (TKV) using magnetic resonance imaging (MRI) is a valuable approach for monitoring disease progression in autosomal dominant polycystic kidney disease (PKD) and is becoming more common in preclinical studies using animal models. Manual contouring of kidney MRI areas [i.e., manual method (MM)] is a conventional, but time-consuming, way to determine TKV. We developed a template-based semiautomatic image segmentation method (SAM) and validated it in three commonly used PKD models: Cys1cpk/cpk mice, Pkd1RC/RC mice, and Pkhd1pck/pck rats (n = 10 per model). We compared SAM-based TKV with that obtained by clinical alternatives including the ellipsoid formula-based method (EM) using three kidney dimensions, the longest kidney length method (LM), and MM, which is considered the gold standard. Both SAM and EM presented high accuracy in TKV assessment in Cys1cpk/cpk mice [interclass correlation coefficient (ICC) ≥ 0.94]. SAM was superior to EM and LM in Pkd1RC/RC mice (ICC = 0.87, 0.74, and <0.10 for SAM, EM, and LM, respectively) and Pkhd1pck/pck rats (ICC = 0.59, <0.10, and <0.10, respectively). Also, SAM outperformed EM in processing time in Cys1cpk/cpk mice (3.6 ± 0.6 vs. 4.4 ± 0.7 min/kidney) and Pkd1RC/RC mice (3.1 ± 0.4 vs. 7.1 ± 2.6 min/kidney, both P < 0.001) but not in Pkhd1PCK/PCK rats (3.7 ± 0.8 vs. 3.2 ± 0.5 min/kidney). LM was the fastest (∼1 min) but correlated most poorly with MM-based TKV in all studied models. Processing times by MM were longer for Cys1cpk/cpk mice, Pkd1RC/RC mice, and Pkhd1pck.pck rats (66.1 ± 7.3, 38.3 ± 7.5, and 29.2 ± 3.5 min). In summary, SAM is a fast and accurate method to determine TKV in mouse and rat PKD models.NEW & NOTEWORTHY Total kidney volume (TKV) is a valuable readout in preclinical studies for autosomal dominant and autosomal recessive polycystic kidney diseases (ADPKD and ARPKD). Since conventional TKV assessment by manual contouring of kidney areas in all images is time-consuming, we developed a template-based semiautomatic image segmentation method (SAM) and validated it in three commonly used ADPKD and ARPKD models. SAM-based TKV measurements were fast, highly reproducible, and accurate across mouse and rat ARPKD and ADPKD models.[Abstract] [Full Text] [Related] [New Search]