These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Assisted distillation cleanup of pesticide residues in animal fats: new beadless distillation tube.
    Author: Heath AB, Black RR.
    Journal: J Assoc Off Anal Chem; 1987; 70(5):862-5. PubMed ID: 3680126.
    Abstract:
    A new assisted distillation tube has been developed which contains no glass beads or glass wool. The sample is injected into the top of the tube, and a septum is not required. Large ground-glass joints (10/19) are used at the gas inlet and at the Florisil trap connection for maximum strength. Existing assisted distillation apparatus was easily modified to accept the new tubes. Recoveries of 9 organochlorine pesticides from butter and cattle fat ranged from 87 to 104% at a tube temperature of 230 degrees C and a nitrogen flow rate of 250 mL/min. No significant change occurred in recoveries of 8 of the 9 pesticides after 85 uses of the beadless tube. Only the recovery of HCB from butter decreased, from 95 to 80%, after 51 runs. The new tube was compared with the Unitrex glass bead-packed concentric tube at flow rates of 230, 400, and 600 mL nitrogen/min. Recoveries from the Unitrex tube were similar to those of the beadless tube for all pesticides except DDT which was significantly lower, indicating incomplete distillation at 250 mL/min and possible partial breakdown at 400 and 600 mL/min. A procedure is introduced for pressurized solvent washing of distillation tubes. This procedure is more efficient than vacuum washing.
    [Abstract] [Full Text] [Related] [New Search]