These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Intranodal dynamic contrast-enhanced CT lymphangiography and dynamic contrast-enhanced MR lymphangiography in microminipig. Author: Tanahashi Y, Shoda S, Kawada H, Ando T, Nagata S, Takasu M, Hyodo F, Goshima S, Mori T, Matsuo M. Journal: Eur Radiol; 2023 May; 33(5):3165-3171. PubMed ID: 36814031. Abstract: OBJECTIVES: To evaluate the feasibility and image quality of intranodal dynamic contrast-enhanced CT lymphangiography (DCCTL) and dynamic contrast-enhanced MR lymphangiography (DCMRL) in microminipigs. METHODS: Our institution's committee for animal research and welfare provided approval. Three microminipigs underwent DCCTL and DCMRL after inguinal lymph node injection of 0.1 mL/kg contrast media. Mean CT values on DCCTL and signal intensity (SI) on DCMRL were measured at the venous angle and thoracic duct (TD). The contrast enhancement index (CEI; increase in CT values pre- to post-contrast) and signal intensity ratio (SIR; SI of lymph divided by SI of muscle) were evaluated. The morphologic legibility, visibility, and continuity of lymphatics were qualitatively evaluated using a 4-point scale. Two microminipigs underwent DCCTL and DCMRL after lymphatic disruption and the detectability of lymphatic leakage was evaluated. RESULTS: The CEI peaked at 5-10 min in all microminipigs. The SIR peaked at 2-4 min in two microminipigs and at 4-10 min in one microminipig. The peak CEI and SIR values were 235.6 HU and 4.8 for venous angle, 239.4 HU and 2.1 for upper TD, and 387.3 HU and 2.1 for middle TD. The visibility and continuity of upper-middle TD scores were 4.0 and 3.3-3.7 for DCCTL, and 4.0 and 4.0 for DCMRL. In the injured lymphatic model, both DCCTL and DCMRL demonstrated lymphatic leakage. CONCLUSIONS: DCCTL and DCMRL in a microminipig model enabled excellent visualization of central lymphatic ducts and lymphatic leakage, indicating the research and clinical potential of both modalities. KEY POINTS: • Intranodal dynamic contrast-enhanced computed tomography lymphangiography showed a contrast enhancement peak at 5-10 min in all microminipigs. • Intranodal dynamic contrast-enhanced magnetic resonance lymphangiography showed a contrast enhancement peak at 2-4 min in two microminipigs and at 4-10 min in one microminipig. • Both intranodal dynamic contrast-enhanced computed tomography lymphangiography and dynamic contrast-enhanced magnetic resonance lymphangiography demonstrated the central lymphatic ducts and lymphatic leakage.[Abstract] [Full Text] [Related] [New Search]