These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Methods of measurement of thermal thresholds. Author: Claus D, Hilz MJ, Hummer I, Neundörfer B. Journal: Acta Neurol Scand; 1987 Oct; 76(4):288-96. PubMed ID: 3687380. Abstract: Thermal tests were performed in 117 healthy subjects on the face, wrist and leg; 32 were tested on the legs with different rates of cooling and warming. Additionally 2 groups of diabetics (37 patients) were tested. Thermotesting was most sensitive on the legs using a rate of temperature change of 2.5-2.8 oC/s. Warm and cold perception should be tested separately. Cold perception testing is most sensitive. Combined tests of warm and cold thresholds as well as the testing of cool pain and heat pain do not improve results. Abnormal cold perception may be an early indicator of diabetic small fibre polyneuropathy, leading to cold trauma and ulcers on the feet.[Abstract] [Full Text] [Related] [New Search]