These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: Role of recombinant Histoplasma capsulatum 100-kilodalton antigen in the diagnosis of histoplasmosis among HIV/AIDS patients: Antigenuria and antibodies detection.
    Author: Toscanini MA, Laboccetta CR, Videla Garrido A, Posse GB, Capece P, Valdez RM, Chacón YA, González Maglio D, Nusblat AD, Cuestas ML.
    Journal: Mycoses; 2023 Jul; 66(7):609-620. PubMed ID: 37029519.
    Abstract:
    BACKGROUND: Diagnosing progressive disseminated histoplasmosis (PDH) is still challenging in many countries where this disease is highly endemic. Definitive diagnosis is established by culture and/or by cytology/histopathology but both procedures have limited sensitivity and cultures are time-consuming. Antibodies detection by immunodiffusion has a low sensitivity in immunocompromised individuals. Commercially available antigen detection assays have high sensitivity in PDH cases; however, they are expensive and only performed in few laboratories. AIMS: To describe the potential use of a novel ELISA for antibodies testing and a dot blot assay for antigen testing for diagnosing PDH using the recombinant 100 kDa protein of Histoplasma capsulatum (Hcp100) and their polyclonal antibodies as novel reagents, respectively. METHODS: Serum and urine samples from a cohort of patients with HIV/AIDS and proven PDH were studied for the detection of anti-Hcp100 antibodies by ELISA and Hcp100 antigen by dot blot, respectively. Sensitivity, specificity and cross-reactions with other diseases were estimated for each assay and compared with those obtained using histoplasmin (HMN) as a reagent for antibodies detection by ELISA and immunodiffusion, and using a commercial antigenuria test. RESULTS: Antibodies detection by the Hcp100 ELISA demonstrated 78.6% sensitivity and 88.4% specificity, versus 85.7% sensitivity and 81.0% specificity for the HMN ELISA and 26.1% sensitivity and 100% specificity for the immunodiffusion assay. Antigen detection by the Hcp100 dot blot demonstrated 89.3% sensitivity and 97.0% specificity versus 82.1% sensitivity and 90.9% specificity for the commercial test. CONCLUSION: The immunoassays described herein based on Hcp100 would be a valuable screening tool for diagnosing PDH.
    [Abstract] [Full Text] [Related] [New Search]