These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: 18F-fluorocholine PET/MRI versus ultrasound and sestamibi for the localization of parathyroid adenomas.
    Author: Noltes ME, Rotstein L, Eskander A, Kluijfhout WP, Bongers P, Brouwers AH, Kruijff S, Metser U, Pasternak JD, Veit-Haibach P.
    Journal: Langenbecks Arch Surg; 2023 Apr 20; 408(1):155. PubMed ID: 37079138.
    Abstract:
    PURPOSE: Accurate preoperative localization is imperative to facilitate a minimally invasive parathyroidectomy (MIP) in primary hyperparathyroidism (pHPT). This study aims to compare the diagnostic value of standard-of-care localization techniques (ultrasound [US] and 99mTechnetium (99mTc) -sestamibi scintigraphy) to [F-18]-fluorocholine positron emission tomography/magnetic resonance imaging (FCH-PET/MRI) to determine the additional clinical usefulness of PET/MRI in a Canadian cohort. METHODS: We conducted a prospective, appropriately powered, study to compare the diagnostic value of -FCH PET/MRI to that of the US and 99mTc-sestamibi scintigraphy for localization of parathyroid adenomas in a patient with pHPT. The primary outcome was the per-lesion sensitivity and positive predictive value (PPV) of FCH-PET/MRI, US, and 99mTc-sestamibi scintigraphy. Intraoperative surgeon localization, parathormone levels, and histopathological findings were used as reference standards. RESULTS: Forty-one patients underwent FCH-PET/MRI of which 36 patients had parathyroidectomy. In these 36 patients, 41 parathyroid lesions were histologically confirmed as adenomas or hyperplastic glands. Per-lesion sensitivity of FCH-PET/MRI was 82.9% and of US and 99mTc-sestamibi scintigraphy combined at 50.0%, respectively. The sensitivity of FCH-PET/MRI was superior to that of US and 99mTc-sestamibi scintigraphy (p = 0.002). In the 19 patients in whom both US and 99mTc-sestamibi scintigraphy were negative, PET/MRI correctly identified the parathyroid adenoma in 13 patients (68%). CONCLUSIONS: FCH-PET/MRI is a highly accurate imaging modality for localization of parathyroid adenomas in a tertiary center in North America. It is a superior functional imaging modality to 99mTc-sestamibi scintigraphy alone and more sensitive for localization of parathyroid lesions than US and 99mTc-sestamibi scintigraphy combined. This imaging modality could become the most valuable preoperative localization study given its superior performance in localizing parathyroid adenomas.
    [Abstract] [Full Text] [Related] [New Search]