Title: Evaluation of ventricular function with gated cardiac magnetic resonance imaging. Author: Osbakken M, Yuschok T. Journal: Cathet Cardiovasc Diagn; 1986; 12(3):156-60. PubMed ID: 3731263. Abstract: To determine the feasibility of using planar images obtained with gated cardiac magnetic resonance imaging (MRI) techniques to evaluate ventricular contractile function, cardiac chamber volume (V), and ejection fraction (EF) were calculated using MR images obtained in five previously catheterized patients. Patients were imaged with a .15-Tesla 55-cm bore magnet using the ECG to gate the images. Spin echo pulse sequences (30/500, TE/TR) were used to produce images in the transverse (T), coronal (C), and sagittal (S) planes at end diastole (ED) and end systole (ES). Slice thickness was 1.5 cm, with 2-mm resolution. A calibration grid was imaged in each plane to determine correction factors. Cardiac chamber areas were determined via planimetry. An area-length-volume algorithm was used to obtain EDV and ESV. Three combinations of biplane images in ES and ED were used (T/C, T/S, C/S). Volume data were used to calculate EF. Contrast ventriculogram volumes tended to be greater than MRI volumes, but EFs were similar with both techniques. In conclusion, gated cardiac MR images can be used to evaluate the ventricular function parameters of volume and ejection fraction.[Abstract] [Full Text] [Related] [New Search]