These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Myocardial Flow Assessment After Heart Transplantation Using Dynamic Cadmium-Zinc-Telluride Single-Photon Emission Computed Tomography With 201Tl and 99mTc Tracers and Validated by 13N-NH3 Positron Emission Tomography. Author: Ko KY, Ko CL, Lee CM, Cheng JS, Wu YW, Hsu RB, Chen YS, Wang SS, Yen RF, Cheng MF. Journal: Circ Cardiovasc Imaging; 2023 Jun; 16(6):e015034. PubMed ID: 37313753. Abstract: BACKGROUND: Cardiac allograft vasculopathy (CAV) is an obliterative and diffuse form of vasculopathy and is the most common cause of long-term cardiovascular mortality in heart transplant patients. This study aimed to investigate the diagnostic performance of 99mTc and 201Tl tracers in the assessment of CAV using cadmium-zinc-telluride (CZT) single-photon emission computed tomography (SPECT) for myocardial blood flow (MBF) and myocardial flow reserve (MFR) quantification, which was further validated using 13 N-NH3 positron emission tomography (PET). METHODS: Thirty-eight patients with prior heart transplantation who underwent CZT SPECT and 13 N-NH3 PET dynamic scans were included in this study. CZT SPECT with 99mTc-sestamibi was used in the first 19 patients and 201Tl-chloride for the remaining patients. To determine the diagnostic accuracy of angiographically defined moderate-to-severe CAV, the analysis included patients who underwent angiographic examinations within 1 year of their second scan. RESULTS: There were no significant differences in the patient characteristics between the 201Tl and 99mTc tracer groups. Both 201Tl and 99mTc CZT SPECT-derived stress MBF and MFR values globally and in 3 coronary territories showed good correlations with 13 N-NH3 PET. The 201Tl and 99mTc cohorts did not differ significantly in the correlation coefficients of CZT SPECT versus PET for MBF and MFR, except for stress MBF (201Tl:0.95 versus 99mTc:0.80, P=0.03). 201Tl and 99mTc CZT SPECT were satisfactory for detecting PET MFR <2.0 (201Tl area under the curve, 0.92 [0.71-0.99], 99mTc area under the curve, 0.87 [0.64-0.97]) and angiographically defined moderate-to-severe CAV, and CZT SPECT results were comparable to that of 13 N-NH3 PET (CZT area under the curve, 0.90 [0.70-0.99], PET area under the curve, 0.86 [0.64-0.97]). CONCLUSIONS: This small study suggests that CZT SPECT using 201Tl and 99mTc tracers showed comparable MBF and MFR, and the results correlated well with those of 13 N-NH3 PET. Hence, CZT SPECT with 201Tl or 99mTc tracers can be used to detect moderate-to-severe CAV in patients with prior heart transplantation. However, validation using larger studies is warranted.[Abstract] [Full Text] [Related] [New Search]