These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Indoor (residential) and ambient particulate matter associations with urinary oxidative stress biomarkers in a COPD cohort. Author: Maccarone J, Grady ST, Moy ML, Hart JE, Kang CM, Coull BA, Schwartz JD, Koutrakis P, Zhang J, Garshick E. Journal: Sci Total Environ; 2023 Nov 01; 897():165352. PubMed ID: 37419349. Abstract: OBJECTIVES: Oxidative stress contributes to chronic obstructive pulmonary disease (COPD) pathophysiology. Associations between indoor (residential) exposure to particulate matter ≤2.5 μm in diameter (PM2.5) and one of its components, black carbon (BC), and oxidative stress are ill-defined. METHODS: Between 2012 and 2017, 140 patients with COPD completed in-home air sampling over one week intervals, followed by collection of urine samples to measure oxidative stress biomarkers, malondialdehyde (MDA), a marker of lipid peroxidation, and 8-hydroxy-2' -deoxyguanosine (8-OHdG), a marker of oxidative DNA damage. Ambient (central site) BC and PM2.5 were measured, and the ratio of indoor/ambient sulfur in PM2.5, a surrogate for residential ventilation and particle infiltration, was used to estimate indoor BC and PM2.5 of outdoor origin. Mixed effects linear regression models with a participant-specific random intercept were used to assess associations with oxidative biomarkers, adjusting for personal characteristics. RESULTS: There were positive associations (% increase per IQR; 95 % CI) of directly measured indoor BC with total MDA (6.96; 1.54, 12.69) and 8-OHdG (4.18; -0.67, 9.27), and similar associations with both indoor BC of outdoor origin and ambient BC. There were no associations with directly measured indoor PM2.5, but there were positive associations between indoor PM2.5 of outdoor origin and total MDA (5.40; -0.91, 12.11) and 8-OHdG (8.02; 2.14, 14.25). CONCLUSIONS: In homes with few indoor combustion sources, directly measured indoor BC, estimates of indoor BC and PM2.5 of outdoor origin, and ambient BC, were positively associated with urinary biomarkers of oxidative stress. This suggests that the infiltration of particulate matter from outdoor sources, attributable to traffic and other sources of combustion, promotes oxidative stress in COPD patients.[Abstract] [Full Text] [Related] [New Search]