These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Pacemaker-lead-associated thrombosis in dogs: a multicenter retrospective study. Author: McGrath C, Dixon A, Hirst C, Bode EF, DeFrancesco T, Fries R, Gordon S, Hogan D, Martinez Pereira Y, Mederska E, Ostenkamp S, Sykes KT, Vitt J, Wesselowski S, Payne JR. Journal: J Vet Cardiol; 2023 Oct; 49():9-28. PubMed ID: 37541127. Abstract: INTRODUCTION: Pacemaker implantation is the treatment of choice for clinically relevant bradyarrhythmias. Pacemaker-lead-associated thrombosis (PLAT) occurs in 23.0-45.0% of people with permanent transvenous pacemakers. Serious thromboembolic complications are reported in 0.6-3.5%. The incidence of PLAT in dogs is unknown. ANIMALS, MATERIALS AND METHODS: multicenter retrospective study of seven centers with 606 client-owned dogs undergoing permanent pacemaker implantation between 2012 and 2019. 260 dogs with a transvenous pacemaker with echocardiographic follow-up, 268 dogs with a transvenous pacemaker without echocardiographic follow-up and 78 dogs with an epicardial pacemaker. RESULTS: 10.4% (27/260) of dogs with transvenous pacemakers and echocardiographic follow-up had PLAT identified. The median time to diagnosis was 175 days (6-1853 days). Pacemaker-lead-associated thrombosis was an incidental finding in 15/27 (55.6%) dogs. Of dogs with a urine protein:creatinine ratio measured at pacemaker implantation, dogs with PLAT were more likely to have proteinuria at pacemaker implantation vs. dogs without PLAT (6/6 (100.0%) vs. 21/52 (40.4%), P=0.007). Urine protein:creatinine ratio was measured in 12/27 (44.4%) dogs at PLAT diagnosis, with proteinuria identified in 10/12 (83.3%) dogs. Anti-thrombotic drugs were used following the identification of PLAT in 22/27 (81.5%) dogs. The thrombus resolved in 9/15 (60.0%) dogs in which follow-up echocardiography was performed. Dogs with PLAT had shorter survival times from implantation compared to those without PLAT (677 days [9-1988 days] vs. 1105 days [1-2661 days], P=0.003). CONCLUSIONS: Pacemaker-lead-associated thrombosis is identified in 10.4% (27/260) of dogs following transvenous pacing, is associated with proteinuria, can cause significant morbidity, and is associated with reduced survival times.[Abstract] [Full Text] [Related] [New Search]