These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Search MEDLINE/PubMed


  • Title: A novel CS-NET architecture based on the unification of CNN, SVM and super-resolution spectrogram to monitor and classify blood pressure using photoplethysmography.
    Author: Pankaj, Kumar A, Komaragiri R, Kumar M.
    Journal: Comput Methods Programs Biomed; 2023 Oct; 240():107716. PubMed ID: 37542944.
    Abstract:
    CONTEXT: Continuous blood pressure (BP) monitoring plays an important role while treating various cardiovascular diseases and hypertension. A high correlation between arterial blood pressure (ABP) and Photoplethysmogram (PPG) signal enables using a PPG signal to monitor and classify BP continuously. Control of BP in realtime is the basis for the prevention of hypertension. PROPOSED APPROACH: This work proposes a CS-NET architecture by unifying CNN and SVM approaches to classify BP using PPG signals. The main objective of the CS-NET method is to establish an accurate and reliable algorithm for the ABP classification. METHODOLOGY: ABP signals are labeled normal and abnormal using the hypertension criteria the American College of Cardiology (ACC)/American Heart Association (AHA) laid down. The proposed CS-NET model incorporates three critical steps in three successive stages. The first stage includes converting a preprocessed PPG signal into a time-frequency (TF) representation called a super-resolution spectrogram by superlet transform. The second stage uses a convolutional neural network (CNN) model with several hidden layers to extract morphological features from every PPG super-resolution spectrogram. The third stage uses a support vector machine (SVM) classifier to classify the PPG signal. RESULTS: PPG signals are used to train and test the proposed model. The performance of the proposed CS-NET method is tested using MIMIC-II, MIMIC-III, and PPG-BP-figshare database in terms of accuracy and F1 score. Moreover, the CS-NET method achieves better results with high accuracy when compared with other benchmark approaches that require an electrocardiogram signal for reference. CONCLUSIONS: The proposed model achieved an aggregate classification accuracy of 98.21% across a five-fold cross-validation technique, making it a reliable approach for BP classification in clinical settings and realtime monitoring.
    [Abstract] [Full Text] [Related] [New Search]