These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Search MEDLINE/PubMed
Title: Assessment of Thoracic Endovascular Aortic Repair Using Relay Proximal Scallop: Results of a French Prospective Multicentre Study. Author: Derycke L, Tomasi J, Desgranges P, Pesteil F, Plissonier D, Pernot M, Millon A, Martinez R, Chakfe N, Alsac JM. Journal: Eur J Vasc Endovasc Surg; 2023 Dec; 66(6):821-829. PubMed ID: 37567339. Abstract: OBJECTIVE: A proximal scallop design allows aortic arch repair without complex endovascular manipulation in the aortic arch. The aim was to assess the safety and efficacy at one year of the Relay proximal scallop stent graft. METHODS: A prospective multicentre study evaluated consecutive patients treated with the Relay proximal scallop stent graft in 10 French aortic centres. All consecutive patients eligible for elective thoracic endovascular repair with proximal scallop in the 10 participating centres between January 2015 and July 2018 were included. Primary endpoints were 30 day mortality, stroke, and spinal cord ischaemia (SCI) rates. Outcomes including safety and efficacy, technical and clinical success, all cause death, neurological events, vessel patency, and device specific complications were analysed. Survival and survival without severe complications were estimated using Kaplan-Meier estimates. RESULTS: Ten aortic centres treated 40 patients for thoracic aortic aneurysm (45%), penetrating atherosclerotic aneurysm (30%), and dissection (25%). Half of the procedures (50%) targeted zone 0 of the aortic arch (zone 0 in 17.5% and zones 0/1 in 32.5%), 37.5% targeted zone 2 (35% zone 2 alone; 2.5% zones 1/2), and 15% targeted zone 1 (12.5% zone 1 alone). Median follow up was one year. Thirty day mortality, stroke, and SCI rates were 10%, 5%, and 0% respectively. Primary technical success was 95%. Type Ia, Ib, and III endoleaks rates were 5.4%, 0%, and 0% respectively at one month. The overall mortality rate at one year was 17.5%. Aneurysm expansion was > 5 mm in one case at one year associated with type Ia endoleak (3%). There was no supra-aortic trunk thrombosis, one (2%) graft kink, and no migration. CONCLUSION: One year outcomes showed that the Relay proximal scallop stent graft is an acceptable answer to thoracic aortic disease to deal with short proximal landing zones.[Abstract] [Full Text] [Related] [New Search]